PN 9000-133-VE, Rev U
Alarm Contact Connections
The WDG-V Analyzer has five (5) alarm contacts, one (1) Service alarm, one (1)
Data Valid alarm, and three (3) configurable process alarms.
Standard Alarm Connections
Service Alarm Relay
This relay is used to determine if there is a problem with the
analyzer. This relay is normally open. Contacts are closed when
in normal mode. The relay will be open when there is a problem
with the analyzer or on loss of power.
Data Valid Relay
This relay is used to determine if the output is representative
of the process. This relay is normally open. Contacts are closed
when in normal mode. Contacts are open when there is a prob-
lem with the analyzer, when the analyzer is calibrating, warming
up, when the analyzer is in diagnostic mode, or on loss of power.
Remote Calibration Unit (Optional)
Contact Input
There is one Contact Input peripheral on the WDG-V.
An auto calibration can be initiated using the contact input
peripheral. (Only with the RCU option).
Auto calibration must be selected in the
Configuration
menu.
Remote Calibration Unit
Interface
The WDG-V has five solenoid valve drivers that are compatible
with AMETEK’s Remote Calibration Unit (RCU).
See “Remote Calibration Unit Connections” in Chapter 2 for
wiring/interface details.
Overview
|
1-11
Содержание WDG-V
Страница 1: ...WDG V WDG VC WDG VCM WDG VM Combustion Analyzer USER MANUAL PN 9000 133 VE Rev U 5000 017 PI rA...
Страница 12: ...PN 9000 133 VE Rev U This page intentionally left blank xii Thermox WDG V VC VCM VM...
Страница 60: ...PN 9000 133 VE Rev U Figure 2 16 RCU Connections 2 34 Thermox WDG V VC VCM VM...
Страница 93: ...PN 9000 133 VE Rev U Figure 3 4 Thermocouple replacement Maintenance and Troubleshooting 3 19...
Страница 97: ...PN 9000 133 VE Rev U Figure 3 6 Flow sensor replacement Maintenance and Troubleshooting 3 23...
Страница 101: ...PN 9000 133 VE Rev U Figure 3 9 Combustibles Block Heater Replacement Maintenance and Troubleshooting 3 27...
Страница 103: ...PN 9000 133 VE Rev U Figure 3 10 Sensor board removal Maintenance and Troubleshooting 3 29...
Страница 124: ...PN 9000 133 VE Rev U This page intentionally left blank 4 10 Thermox WDG V VC VCM VM...