STRATOS WITH ENCLOSURE:
Install Manual
25MAR2022 | 630-00147 C
20
INSTALLATION
STRATOS WITH ENCLOSURE: SECTION 4
INSTALLING THE DOME
1. The top panels of the enclosure will have a
slotted bracket installed between the panel
and the dome.
The dome has threaded attachment points
that rest inside of the slots and a nut that is
attached for securement. See Figure 4-15.
Figure 4-15
INSTALLING THE TOP
LANDING GATE
(IF NECESSARY)
NOTE: If the call send switch is installed in the gate, the
wires are routed between the gate and to the top of the
tower. If the call send is located outside the gate, the
wires are routed from the gate to the call send box and
then from the box to the top of the tower.
2. Create the necessary space below the gate sill
so the wire can be routed into the gate post
through the wire routing slot. See Figure 4-16.
Post slots
Hole
plugs
Wire routing
slots
Sill
mounting
slots
Figure 4-16
3. Remove small screws and post cover on the
latch side of the landing gate with a No. 1
Phillips screwdriver.
4. Open landing gate door and remove 4X hole
plugs.
5. Place the gate at the upper landing and center
the gate opening with the platform.
6. Use the holes in the gate threshold to screw
the gate down to the landing.
7. Run the wire through the wire routing slot and
to the interlock.