STRATOS WITH ENCLOSURE:
Install Manual
25MAR2022 | 630-00147 C
13
PREPARATION
STRATOS WITH ENCLOSURE: SECTION 3
Enclosure
alignment
plate
Figure 3-3
NOTE: Enclosure needs to have all screws and plastic
washers secure to prevent rusting if the unit is located
outside. After the unit is secured and anchored, the plate
should be removed.
5.
Depending on the application, specifically if
it is a wall side first, you may not have access
to the bolt holes when it is assembled. Use
the fastener kit specified on the installation
drawing to assemble panels.
See Figure 3-4.
Bolts and caps (2)
Bolt together
wall-side panels
Figure 3-4
6.
Place the bolts through the tower side panels
into the wall panels.
See Figure 3-5.
You may have
to shim this
side if a gap is
at the bottom
You may
have to shim
under here if
gap is at the
top
Figure 3-5
7.
Verify the spacing for the tower side panels and
decide if you are going to need to shim the VPL
unit. The tower side panels' edge needs to be
parallel with the wall. Depending on the angle,
if it is open at the bottom, shim the wall, if it is
open at the top, shim the tower.