STRATOS WITH ENCLOSURE:
Install Manual
25MAR2022 | 630-00147 C
21
INSTALLATION
STRATOS WITH ENCLOSURE: SECTION 4
8. Cut the wire to length and strip the wire
conductors.
9. Connect the interlock wires and the gate call /
send switch (if equipped). See Figure 4-17.
Figure 4-17
The lift control board has a short circuit protection
feature that will disable landing circuits if the wires
are wired incorrectly. No landing functions will work
and all landing status lights will be OFF when in this
mode. Circuits will automatically reset when the
wiring is corrected.
NOTICE
10. Reinstall, gate post covers, and hole plugs.
NOTE: Gates are field reversible (contact Ameriglide
Technical Service for instructions).
SETTING THE UPPER LIMIT
SWITCH
Typically only the upper limit switch will need to be
adjusted.
Raise the platform so it is level with the upper
landing.
Loosen the bolts on the upper limit switch assembly.
Slide the assembly down until the switch makes
contact with the carriage and makes a clicking
sound. Re-tighten the bolts. See Figure 4-18.