5
7. A program
should be
established for the inspection and cleaning of lint in the heating unit area, exhaust
ductwork, and inside the dryer. The frequency of inspection and cleaning can best be determined from
experience at each location.
WARNING:
The collection of lint in the burner area and exhaust ductwork can create a potential fire
hazard.
8. For personal safety, the dryer
must be
electrically grounded in accordance with local codes and/or the
National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION or in Canada, the Canadian Electrical
Codes Parts 1 & 2 CSA C22.1-1990 or LATEST EDITION.
NOTE
: Failure to do so will VOID THE WARRANTY.
9.
UNDER NO CIRCUMSTANCES
should the dryer door switches, lint door switch, heat safety circuit
ever be disabled.
WARNING: PERSONAL INJURY or FIRE COULD RESULT.
10. This dryer is not to be used in the presence of dry cleaning solvents or fumes.
11. Remove articles from the dryer as soon as the drying cycle has been completed.
WARNING:
Articles left in the dryer after the drying and cooling cycles have been completed can
create a fire hazard.
12.
DO NOT
operate steam dryers with more than 125 PSI (8.62 bars) steam pressure. Excessive steam
pressure can damage steam coil and/or harm personnel.
13. Replace leaking flexible hoses or other steam fixtures immediately.
DO NOT
operate the dryer with
leaking flexible hoses.
PERSONAL INJURY MAY RESULT.
14. The normal PH level for copper type steam coils
must be
maintained between a value of 8.5 to 9.5. For
steel type steam coils the PH level
must be
maintained between a value of 9.5 to 10.5. These limits are set
to limit the acid attack of the steam coils.
IMPORTANT:
Coil failure due to improper PH level will VOID THE WARRANTY.
15.
READ AND FOLLOW ALL CAUTION AND DIRECTION LABELS ATTACHED TO THE
DRYER.
16. For safety, proper operation, and optimum performance, the dryer
must not be
operated with a load less
than sixty-six percent (66%), 50 pounds (22.67 kg) of its rated capacity.
WARNING: YOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPLY AND
THE GAS SUPPLY OR THE STEAM SUPPLY BEFORE ANY COVERS OR
GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS
FOR CLEANING, ADJUSTING, INSTALLATION, OR TESTING OF ANY
EQUIPMENT PER OSHA
(Occupational Safety and Health Administration)
STANDARDS.