23
Single-Phase (1Ø) Electrical Connections Leads
Black
+
Positive
White
+
Neutral
Green
+
Ground
or
L2
If local codes permit, power to the dryer can be made by the use of a flexible U.L. listed power
cord/pigtail (wire size
must conform
to rating of dryer), or the dryer can be hard wired directly to
the service breaker panel. In both cases, a strain relief
must be
installed where the wiring enters
the dryer.
2) 3-Phase (3ø) Wiring Connections/Hookup Non-Reversing Models Only
The electrical connections on
ALL
3-phase (3ø) gas and steam dryers are made into the rear
service box located at the upper left area of the dryer. Electrical connections for electrically heated
dryers are made in the electric oven area located at the upper rear area of the dryer.
NOTE: A CIRCUIT SERVICING EACH DRYER
MUST BE
PROVIDED.
If local codes permit, power to a gas or steam dryer can be made by the use of a flexible U.L. listed
power cord/pigtail (wire size
must conform
to rating of dryer), or the dryer can be hard wired
directly to the service breaker panel. In
ALL
cases, a strain relief
must be
installed where the
wiring enters the dryer.
Содержание ML-75DIII
Страница 22: ...18 ...