TROUBLESHOOTING INFORMATION

 

 

 

 

 

NOTE:  Before starting this procedure ensure the changer is plugged in, the ON/OFF switch is on, the hoppers are 

full of coins,  and all wire harnesses are connected securely and correctly. 

The wires exiting the red connectors should point away from the board!! 

 

              TECHNICAL FLOW DIAGRAM 

 SERIES

 

IS THE

"EMPTY" LED

"ON"?

Yes

PRESS AND HOLD THE

"DUMP BUTTON " ON

THE MAIN LOGIC

BOARD. WHAT

NUMBER(S) ARE

DISPLAYED?

#02

#01

#04

#10

Hopper Exit window
is blocked. Please
do the following.
1. Remove all the
coins.
2. Take off the
Track side cover of
the hopper.
3. Remove the
object from the
window.
4. Reassemble the
hopper.

The hopper has a
low coin shut down.
Please do the
following:
1. Ensure the
hopper is full of
coins. Turn off the
machine, wait 5 sec.
then turn it back on
again.
2 Clean the 3 gold
plates at the bottom
of the hopper where
the coins are poured
in with a scotch
bright pad or emery
cloth.
3. Check continuity
of the wires from
the gold plates back
to the logic board.

The hopper is

jammed.

The hopper
overpaid by 2
to many coins
and was shut
down. Replace
the hopper or
the hopper
harness.

NO

Is the GREEN

LED on the

main logic

board on?

Yes

NO

Is the On/

Off (I/O)

switch on?

(I pressed

down?)

Yes

Is the

120VAC plug

pushed into

the bottom of

the logic

board and into

the wall?

Yes

Using a

meter check

the 2-amp

fuse. Is it

good good?

Yes

NO

Check the 120VAC

wall breaker.

Replace the FUSE

then the logic board.

Will the CoinCo bill

acceptor attempt to

pull bills in at all?

Are the RED bill

meter numbers lit

on the main logic

display?

NO

Yes

NO

YES

It appears as if your CoinCo is
dirty or the belts are worn. Please
try the following:
1. Go to Page 7 and perform the
cleaning procedure.
2. If that is unsuccessful inspect
the plastic lower housing for deep
scratches or VANDALISM.
3. If the CoinCo has accepted over
50,000 bills it could need new
belts.

The CoinCo is

flashing an

"ERROR CODE".

Please go to the

CoinCo Error code

section of this

manual. Page 8.

The bill acceptor 
is flashing an 
“ERROR CODE.”  
See the Trouble- 
shooting Guide in 
this manual for 
error codes. 

Will the bill 
acceptor attempt 
to pull bills in at 
all? 

It appears as if your bill acceptor is dirty or 
the belts are worn.  Please try the following: 

1.  Perform the cleaning procedure described 

in the cleaning kit instructions included in 
your information packet. 

2. 

If that is unsuccessful, inspect the plastic 
lower housing for deep scratches or 
VANDALISM.

 

3. 

If the bill acceptor has accepted over 
50,000 bills, it could need new belts.

 

Содержание AC2002

Страница 1: ...ERIES CHANGER OPERATIONS MANUAL MODELS AC2002 2002 1 ARL Listed STD UL 756 Parts Service 888 741 9840 Service Fax 954 917 5204 Sales 800 741 9840 To order parts only visit our website www americanchan...

Страница 2: ...2 Model Number ________________________ Serial Number ________________________ Tested By ________________________ Date ________________________...

Страница 3: ...ranty work It is the end users responsibility to follow cleaning and maintenance procedures as outlined in the validator manual Any unit returned for repair requiring only a cleaning will be charged a...

Страница 4: ...11 Wire Harness Color and Definitions 11 Hopper Coin Token Sizes General Information 12 Validator Interface 12 Main Logic Board Connector Pin Definitions 13 Functional Description of the Series AC2002...

Страница 5: ...ER FOR YOU 1 Disconnect any and all AC power going to the changer Unplug AC line cord from the Power Module Board and from the wall 2 Slide the hoppers out of the cabinet 3 Note You will need to verif...

Страница 6: ...e Filling the Hoppers section 16 In order to continue you will need to purchase electrical cable conduit a standard 3 prong AC wall outlet and 12 gauge wire We highly recommend hiring a licensed elect...

Страница 7: ...red LED numbers are not counting up rapidly on the Main Logic Board s display the dump mode was not accessed Please try again The Dip Switches The AC2002 changer is capable of dispensing coins in man...

Страница 8: ...8 HOPPER PAYOUT TABLE...

Страница 9: ...9...

Страница 10: ...trols the right hopper s payout Refer to the next table to set up your changer for the settings you need Mode Descriptions Some of the modes are self explanatory while others have sub modes built into...

Страница 11: ...ce Hopper error detected Validator Logic Board 1 Red LED a On Steady Standby Mode waiting for bill insertion b Flashing Error mode go to page for error code information c Off The changer Empty LED is...

Страница 12: ...r Validator Interface Interfacing for all MDB Validators No Dip Switches Validator can be factory programmed or it can be configured using the Configuration Card or a Palm Refer to the validator s Ins...

Страница 13: ...per second in the standby mode 2 During the power up mode the main logic board relay clicks twice enabling power 120VAC to the validator When this relay is not enabled it routes 12VDC ground to the o...

Страница 14: ...our own call your distributor or return the defective hopper to American Changer b Indications for a blocked coin optic or bad hopper logic board are that the out of service LED on the outside of the...

Страница 15: ...male socket s pins so that they are not so spread out 2 If the continuity is infinity then replace that hopper QUICK CODE ERROR DEFINITIONS Figure 5 MAIN LOGIC BOARD on back wall of cabinet Press the...

Страница 16: ...16 Dual Hopper Schematics...

Страница 17: ...17...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...ard on Yes NO Is the On Off I O switch on I pressed down Yes Is the 120VAC plug pushed into the bottom of the logic board and into the wall Yes Using a meter check the 2 amp fuse Is it good good Yes N...

Страница 21: ...ins 2 and 7 3 Clean the gold contact plates with steel wool 4 Perform the following steps a Turn the changer off b Ensure that the left hopper plate red connector on the left side of the main logic bo...

Страница 22: ...1 Ensure the dip switch settings are still correct 3 ON only 2 Check the continuity of the brown and purple wires on the hopper s wire harness 3 The hopper is jammed 4 Replace the hopper s wire harne...

Страница 23: ...the area behind the push bar with high pressure or canned air Concentrate on the encoder wheel in the area top center behind the push bar 2 Contact American Changer technical service 888 741 9840 to r...

Страница 24: ...24 Maintenance Information A full size version of the cleaning kit instructions is included in your information packet...

Страница 25: ...9 AC9021 PYRAMID 110V BILL VALIDATOR 10 AC1042 HOPPER EXTENSION CAPACITY 1200 COINS EACH 11 2900 MANUAL PACKET 12 2010 104 LEFT STAINLESS COIN DIVERTER ONLY 13 2010 114 RIGHT STAINLESS COIN DIVERTER O...

Отзывы: