TROUBLESHOOTING GUIDE 

To use the Troubleshooting Guide, match up the problem, then follow the solution suggestions. 

After every step, try operating the changer to see if the problem has been solved. 

 

PROBLEM:

 

SOLUTION:

 

 

A.   

The changer is completely dead.  

(The 

green LED  on the Power Supply Board is 
not lit.)

 

 

1.  

Ensure the changer is plugged in. 

2.  

Ensure  the  ON/OFF  switch  is  rocked  to  the  (1)  position 
(down). 

3.  

Unplug the female end of the line cord from the main logic 
board AC connector and plug it in again tightly. 

4.    Measure  the  AC  voltage  at  the  outlet  or  check  the 

breaker/fuse box.  You can also plug another item into the 
AC  wall  outlet  to  ensure  there  is  power  present  at  the 
outlet. 

4.  

Inspect the AC line cord for cuts or abrasions. 

5.  

Check both fuses on the Main Logic Board. 

6.  

Replace the Main Logic Board. 

7.  

Replace the line cord. 

 

 

B.   

The “Empty LED is lit.  

BOTH HOPPERS 

ARE OUT OF SERVICE

 

1.   Ensure the hoppers are not out of coins.  (There should 

be enough coins in the hoppers to cover the gold low-
level contact plates approximately $30-$40.  These 
plates are located at the bottom of the hoppers where 
you pour the coins.) 

2.   Check the hoppers’ wire harness that extends from the 

back of the plate that the hoppers slide in and out on for 
chipped pieces or other damage.  (Pay close attention to 
pins # 2 and 7.) 

3.  

Clean the gold contact plates with steel wool. 

4.  

Perform the following steps: 

a.   Turn the changer off. 

b.  Ensure that the left hopper plate red connector on 

the left side of the main logic board (MLB) is plugged 
into the bottom connector and that the right is 
plugged into the top connector. 

c.   On the MLB, slide all the dip switches left to the 

“OFF” position. 

d.  On the left dip switch, slide #3 “ON,” enabling a 4-

coin-per-dollar payout. 

e.  On the right dip switch, slide #8 “ON,” disabling the 

top hopper connector and enabling the changer into 
“One Hopper Mode.” 

f. 

Turn the changer on. 

g.  If the “Empty” LED on the front of the changer is 

now off, remove the right hopper and service this 
hopper.  The changer will function in this mode until 
the hopper is fixed.   

h.  If the “Empty” LED is still “ON,” turn the changer off 

and switch the hoppers; then turn the changer back 
on. 

i. 

If the “Empty” LED on the front of the changer is 
now off, remove the right hopper and service this 
hopper.  The changer will function in this mode until 
the hopper is fixed. 

Remember to remove the coin 

chute from the hopper, or the coins will fall into the 
changer instead of into the coin cup! 

  

j. 

If the “Empty” LED is still “ON,”  turn off the 
changer. 

k.  Reverse the hopper's plate connections (top to 

bottom, bottom to top), and repeat steps f thru i.    

Keep in mind that you are troubleshooting the 
hopper plates instead of the hoppers.

 

5.  

Replace the Main Logic Board. 

6.  

Replace both hoppers. 

7.    Replace both hopper plates with the harnesses. 

Содержание AC2002

Страница 1: ...ERIES CHANGER OPERATIONS MANUAL MODELS AC2002 2002 1 ARL Listed STD UL 756 Parts Service 888 741 9840 Service Fax 954 917 5204 Sales 800 741 9840 To order parts only visit our website www americanchan...

Страница 2: ...2 Model Number ________________________ Serial Number ________________________ Tested By ________________________ Date ________________________...

Страница 3: ...ranty work It is the end users responsibility to follow cleaning and maintenance procedures as outlined in the validator manual Any unit returned for repair requiring only a cleaning will be charged a...

Страница 4: ...11 Wire Harness Color and Definitions 11 Hopper Coin Token Sizes General Information 12 Validator Interface 12 Main Logic Board Connector Pin Definitions 13 Functional Description of the Series AC2002...

Страница 5: ...ER FOR YOU 1 Disconnect any and all AC power going to the changer Unplug AC line cord from the Power Module Board and from the wall 2 Slide the hoppers out of the cabinet 3 Note You will need to verif...

Страница 6: ...e Filling the Hoppers section 16 In order to continue you will need to purchase electrical cable conduit a standard 3 prong AC wall outlet and 12 gauge wire We highly recommend hiring a licensed elect...

Страница 7: ...red LED numbers are not counting up rapidly on the Main Logic Board s display the dump mode was not accessed Please try again The Dip Switches The AC2002 changer is capable of dispensing coins in man...

Страница 8: ...8 HOPPER PAYOUT TABLE...

Страница 9: ...9...

Страница 10: ...trols the right hopper s payout Refer to the next table to set up your changer for the settings you need Mode Descriptions Some of the modes are self explanatory while others have sub modes built into...

Страница 11: ...ce Hopper error detected Validator Logic Board 1 Red LED a On Steady Standby Mode waiting for bill insertion b Flashing Error mode go to page for error code information c Off The changer Empty LED is...

Страница 12: ...r Validator Interface Interfacing for all MDB Validators No Dip Switches Validator can be factory programmed or it can be configured using the Configuration Card or a Palm Refer to the validator s Ins...

Страница 13: ...per second in the standby mode 2 During the power up mode the main logic board relay clicks twice enabling power 120VAC to the validator When this relay is not enabled it routes 12VDC ground to the o...

Страница 14: ...our own call your distributor or return the defective hopper to American Changer b Indications for a blocked coin optic or bad hopper logic board are that the out of service LED on the outside of the...

Страница 15: ...male socket s pins so that they are not so spread out 2 If the continuity is infinity then replace that hopper QUICK CODE ERROR DEFINITIONS Figure 5 MAIN LOGIC BOARD on back wall of cabinet Press the...

Страница 16: ...16 Dual Hopper Schematics...

Страница 17: ...17...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...ard on Yes NO Is the On Off I O switch on I pressed down Yes Is the 120VAC plug pushed into the bottom of the logic board and into the wall Yes Using a meter check the 2 amp fuse Is it good good Yes N...

Страница 21: ...ins 2 and 7 3 Clean the gold contact plates with steel wool 4 Perform the following steps a Turn the changer off b Ensure that the left hopper plate red connector on the left side of the main logic bo...

Страница 22: ...1 Ensure the dip switch settings are still correct 3 ON only 2 Check the continuity of the brown and purple wires on the hopper s wire harness 3 The hopper is jammed 4 Replace the hopper s wire harne...