TROUBLESHOOTING GUIDE
To use the Troubleshooting Guide, match up the problem, then follow the solution suggestions.
After every step, try operating the changer to see if the problem has been solved.
PROBLEM:
SOLUTION:
J. The bill validator red status LED flashes a “6 or
7” error code.
1.
Remove the bill stacker from the bill validator.
Cycle the power on/off using the switch on the
Main Logic Board and coast the silver push bar so
that it stops in its fully extended position. Blow
out the area behind the push bar with high
pressure or canned air. Concentrate on the
encoder wheel in the area top center behind the
push bar.
2.
Contact American Changer technical service
(888-741-9840) to repair your bill validator.
K. The bill validators red status LED is on steady,
but it will not accept the bill.
1.
Pull out the lower housing (see validator manual)
and look for something obstructing the bill path.
(i.e., gum, papers, tickets, coins, etc.).
2.
Look inside the Plexiglas case on the side of the
bill validator. Ensure that all the wire harness
plugs are plugged firmly into their white female
sockets.