9.  

Choose  a  height  to  mount  the  changer,  keeping  in  mind  that  a  handicapped  person  in  a 
wheelchair  should  still  be  able  to  insert  a  bill  into  the  bill  validator.    (We  recommend  no 
higher than 4 feet above the ground.)

 

10.  

Have  someone  hold  the  changer  against  the  wall  while  someone  else  marks  the  holes.  

CAUTION:

 

THE  CHANGER  WEIGHS  98  POUNDS;  DO  NOT  EXERT  YOURSELF  SO 

THAT YOU MAY CAUSE AN INJURY. 

11.  

BEFORE  DRILLING  THE  MARKED  HOLES,  ENSURE  THAT  THERE  ARE  NO 
ELECTRICAL  WIRES,  TELEPHONE  LINES,  GAS  OR  WATER  LINES  BEHIND  THE 
WALL.

  

 

12.  

Hold the changer’s back against the wall.  Thread and tighten bolts.

 

13.  

Verify that the machine is securely mounted. 

14.  

If the changer is permanently connected through a conduit, proceed to step #16.

 

15.  

Feed the AC line cord out the bottom or the back of the changer by moving the “L” bracket 
if necessary, and then perform the following:

 

a.  Plug  the  male  end  into  the  AC  wall  outlet.   

Do  not  use  an  extension  cord  unless 

allowed by the building electrical code

.

 

b. 

Important:  

Attach the line cord clamp to the line cord.  Verify it is at the right length 

and  that  the  line  cord  is  not  rubbing  against  any  sharp  edges  or  is  being  strained  in 
any way.  Then mount the line cord clamp to the studs at the hole.  Tighten securely.  
Installation is completed.  Proceed to the “Filling the Hoppers” section.

  

16.  In  order  to  continue,  you  will  need  to  purchase  electrical  cable  conduit,  a  standard  3-

prong  AC  wall  outlet,  and  12-gauge  wire.      We  highly  recommend  hiring  a  licensed 
electrician to perform the following: 

a.   Install  the  conduit  box  on  the  conduit  entering  the  cabinet  in  the lower right side of  

the cabinet. 

b.   Secure  the  3  wires  (hot,  neutral  and  ground)  to  the  AC  wall  outlet;  the ground wire 

should also be directly attached to the cabinet ground terminal. 

c.   Plug the male end into the AC outlet just installed. 

d.   Properly fold the line cord to avoid sharp corners and any other damage. 

17.  Proceed to the “Filling the Hoppers” section. 
 
 

Filling the Hoppers

 

 
When  each  hopper  has  fewer  than  80-100  coins  left,  the  red  “Empty”  LED  will  illuminate  on 
the  front  of  the  changer.    If  you  have  disconnected  your  LED,  make  sure  the  orange  wire  is 
going to the terminal on the LED that has the red wired terminal.  

Whenever the “Empty” 

LED is “ON,” the validator is disabled; and it will no longer accept bills.

 

1.  

Turn OFF the power on the Main Logic Board. 

2.  

Slide the hoppers from the cabinet, and insert the coins through the opening on the top.  

There  must  be  at  least  enough  coins  to  cover  the  two  gold  plates  at  the  bottom  of  the 
hoppers

 (

somewhere between 160 and 1,600 coins, minimum to maximum

). 

 

3.  

Slide the hoppers back into the hopper plate.  

Do not use excessive force!

 

4.  

Turn the power switch to “ON.”  The “Empty” LED is now off, and the bill validator is ready 
to accept bills.

Содержание AC2002

Страница 1: ...ERIES CHANGER OPERATIONS MANUAL MODELS AC2002 2002 1 ARL Listed STD UL 756 Parts Service 888 741 9840 Service Fax 954 917 5204 Sales 800 741 9840 To order parts only visit our website www americanchan...

Страница 2: ...2 Model Number ________________________ Serial Number ________________________ Tested By ________________________ Date ________________________...

Страница 3: ...ranty work It is the end users responsibility to follow cleaning and maintenance procedures as outlined in the validator manual Any unit returned for repair requiring only a cleaning will be charged a...

Страница 4: ...11 Wire Harness Color and Definitions 11 Hopper Coin Token Sizes General Information 12 Validator Interface 12 Main Logic Board Connector Pin Definitions 13 Functional Description of the Series AC2002...

Страница 5: ...ER FOR YOU 1 Disconnect any and all AC power going to the changer Unplug AC line cord from the Power Module Board and from the wall 2 Slide the hoppers out of the cabinet 3 Note You will need to verif...

Страница 6: ...e Filling the Hoppers section 16 In order to continue you will need to purchase electrical cable conduit a standard 3 prong AC wall outlet and 12 gauge wire We highly recommend hiring a licensed elect...

Страница 7: ...red LED numbers are not counting up rapidly on the Main Logic Board s display the dump mode was not accessed Please try again The Dip Switches The AC2002 changer is capable of dispensing coins in man...

Страница 8: ...8 HOPPER PAYOUT TABLE...

Страница 9: ...9...

Страница 10: ...trols the right hopper s payout Refer to the next table to set up your changer for the settings you need Mode Descriptions Some of the modes are self explanatory while others have sub modes built into...

Страница 11: ...ce Hopper error detected Validator Logic Board 1 Red LED a On Steady Standby Mode waiting for bill insertion b Flashing Error mode go to page for error code information c Off The changer Empty LED is...

Страница 12: ...r Validator Interface Interfacing for all MDB Validators No Dip Switches Validator can be factory programmed or it can be configured using the Configuration Card or a Palm Refer to the validator s Ins...

Страница 13: ...per second in the standby mode 2 During the power up mode the main logic board relay clicks twice enabling power 120VAC to the validator When this relay is not enabled it routes 12VDC ground to the o...

Страница 14: ...our own call your distributor or return the defective hopper to American Changer b Indications for a blocked coin optic or bad hopper logic board are that the out of service LED on the outside of the...

Страница 15: ...male socket s pins so that they are not so spread out 2 If the continuity is infinity then replace that hopper QUICK CODE ERROR DEFINITIONS Figure 5 MAIN LOGIC BOARD on back wall of cabinet Press the...

Страница 16: ...16 Dual Hopper Schematics...

Страница 17: ...17...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...ard on Yes NO Is the On Off I O switch on I pressed down Yes Is the 120VAC plug pushed into the bottom of the logic board and into the wall Yes Using a meter check the 2 amp fuse Is it good good Yes N...

Страница 21: ...ins 2 and 7 3 Clean the gold contact plates with steel wool 4 Perform the following steps a Turn the changer off b Ensure that the left hopper plate red connector on the left side of the main logic bo...

Страница 22: ...1 Ensure the dip switch settings are still correct 3 ON only 2 Check the continuity of the brown and purple wires on the hopper s wire harness 3 The hopper is jammed 4 Replace the hopper s wire harne...

Страница 23: ...the area behind the push bar with high pressure or canned air Concentrate on the encoder wheel in the area top center behind the push bar 2 Contact American Changer technical service 888 741 9840 to r...

Страница 24: ...24 Maintenance Information A full size version of the cleaning kit instructions is included in your information packet...

Страница 25: ...9 AC9021 PYRAMID 110V BILL VALIDATOR 10 AC1042 HOPPER EXTENSION CAPACITY 1200 COINS EACH 11 2900 MANUAL PACKET 12 2010 104 LEFT STAINLESS COIN DIVERTER ONLY 13 2010 114 RIGHT STAINLESS COIN DIVERTER O...

Отзывы: