DIP
SWITCHES
LEFT HOPPER
ERROR CODE
RIGHT HOPPER
ERROR CODE
LEFT DIGIT
ALWAYS “0.”
IGNORE!
BILL METER/
ERROR CODES
b. Check continuity (0 ohms) and resistance from pins 3 (white) and 10 (black) of the red hopper harnesses.
Make sure both hoppers are full and the changer is turned off.
1.
If the continuity is 0 ohms, replace the main logic board.
c. Pull the hoppers out of the changer, then look at the 12-pin black male connector that sticks out of the
hoppers. Place the continuity checker’s leads on pins 2 & 7.
1.
If the continuity is 0 ohms, replace that hopper’s plate or adjust the hopper’s plate female socket’s pins so
that they are not so spread out.
2.
If the continuity is infinity, then replace that hopper.
QUICK CODE ERROR DEFINITIONS
Figure 5 – MAIN LOGIC BOARD
(on back wall of cabinet)
Press the “DUMP” Button before turning off changer. Match the code to samples
below to find out why the hopper(s) were shut down.
LEFT HOPPER ERRORS
RIGHT HOPPER ERRORS
NO ERRORS
NO ERRORS
LOW COIN LOW COIN
EXIT WINDOW JAM EXIT WINDOW JAM
BAD HOPPER BOARD BAD HOPPER BOARD
JAMMED JAMMED
JACKPOT PREVENTED
JACKPOT PREVENTED
IF THE “EMPTY” LED IS LIT, LOOK FOR CODES FOR BOTH HOPPERS TO BE DISPLAYED.
NOTE: THE METER ON THE MAIN LOGIC BOARD CANNOT BE RESET TO ZERO!!!
0
0 1
0 1
DUMP
BUTTON
0
0 0
0 0
0
0 1
0 0
0
0 2
0 0
0
0 3
0 0
0
0 4
0 0
0
0
1 0
0 0
0
0 0
0 0
0
0 0
0 1
0
0 0
0 2
0
0 0
0 3
0
0 0
0 4
0
0 0
1 0