Command Word 1 (continued)
Bit 4: Reverse_Blend_Direction –
When you command a Blend Move to run, this bit determines the
direction of rotation. Set to “0” for a clockwise Blend Move, ‘1’ for a counter-clockwise Blend
Move.
Bit 3: Reserved –
Must be set to “0”.
Bit 2: Encoder_Registration_Move –
This bit is used with the Relative_Move (Command Word 0, bit 1)
or Absolute_Move (Command Word 0, bit 0) bits. Set this bit to “1” to command an Encoder Regis-
tration Move. This move will run until the encoder count reaches the programmed relative or abso-
lute value and then the move will begin to decelerate and stop. Must equal “0” for normal relative or
absolute moves. A full description of an
Bit 1: Motor_Current_Key1 –
See the description below.
Bit 0: Motor_Current_Key0 –
See the description below.
Description of Motor Current Keys
With the exceptions of the CW/CCW Registration Move commands, it is possible to change the motor current
“on the fly” while in Command Mode. To do this, place the new motor current in Word 8 and set the key bits
as shown below.
Control Word 2: Bit 5, (Key2) – “1”
Control Word 2: Bit 1, (Key1) – “0”
Control Word 2: Bit 0, (Key0) – “1”
This feature does not work with CW/CCW Registration Move commands because Words 8 and 9 are used to
store the Minimum Registration Distance parameter. For all other commands, the Networked Driver will
respond by changing the motor current and writing the new value into the Network Input Data, Word 8. Once
the motor current has been set, reset the key bits to all zeros to prevent further changes to the motor current.
The motor current can be changed at any time, including during a move.
Setting the motor current to an invalid value does not force a command error. The value will be
ignored and the Networked Driver will use the motor current value programmed while in Con-
figuration Mode. Invalid values are:
Value whose last digit is not even
Values outside the range of 1.0 to 6.0 amps on the SD17060E2
Values outside the range of 1.0 to 4.4 amps on the SD31045E2
Содержание SD17060E2
Страница 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0S172 E2 Technology E2 Technology...
Страница 10: ...ABOUT THIS MANUAL Networked Indexer Driver User Manual ADVANCED MICRO CONTROLS INC 10 Notes...
Страница 22: ...UL CUL RECOGNIZED INSTALLATIONS Networked Indexer Driver User Manual ADVANCED MICRO CONTROLS INC 22 Notes...
Страница 54: ...CALCULATING MOVE PROFILES Networked Indexer Driver User Manual ADVANCED MICRO CONTROLS INC 54 Notes...
Страница 88: ...COMMAND MODE DATA FORMAT Networked Indexer Driver User Manual ADVANCED MICRO CONTROLS INC 88 Notes...
Страница 106: ...INSTALLING AN AMCI NETWORKED DRIVER Networked Indexer Driver User Manual ADVANCED MICRO CONTROLS INC 106 Notes...
Страница 130: ...ETHERNET IP EXPLICIT MESSAGING Networked Indexer Driver User Manual ADVANCED MICRO CONTROLS INC 130 Notes...
Страница 134: ...MODBUS TCP CONFIGURATION Networked Indexer Driver User Manual ADVANCED MICRO CONTROLS INC 134 Notes...
Страница 144: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...