Output Data Format
ADVANCED MICRO CONTROLS INC.
5
64
Command Block 6: Program LS Enabling Parameters (continued)
Command Word Bits (continued)
Bit 9:
Machine Speed Enabling.
When reset to ‘0’ the Machine Speed Enabling parameters are left at their
current values. When set to ‘1’, words 2 and 3 define the RPM Enable Low and RPM Enable High
Setpoints for Machine Speed Enabling.
1) Once Machine Speed Enabling has been configured on an output, the only way to remove
the Machine Speed Enabling is by:
a) Using the
Delete Enabling
or
Delete All
bits (bits 6 or 5) in command word 0.
b) Setting both setpoints to zero.
2) A programming error will result if this bit and bit 8 are both set to ‘1’.
Bit 10: Shift Register Position.
When reset to ‘0’ the
Shift Register Bit Number
parameter is left at its
current value. When set to ‘1’, word 4 programs the
Shift Register Bit Number,
which define the
bit position in the shift register used to enable the output.
is on page 25.
2) A programming error will result if this bit and bit 8 are both set to ‘1’.
Word
Result
1
LS Output Point being programmed (1 to 16)
2
RPM Enable Low Setpoint.
Range of -32,767 to +32,767
3
RPM Enable High Setpoint.
Range of -32,767 to +32,767
4-19
Not Used
Word
Result
1
LS Output Point being programmed (1 to 16)
2
Not Used.
(May be used when programming the Machine Speed Enabling.)
3
Not Used.
(May be used when programming the Machine Speed Enabling.)
4
Shift Register Bit Number
(Range of 0, 1 to 256)
When set to ‘0’, shift register enabling is removed from the output
listed in word 1.
5-19
Not Used.
Содержание ANS1 ANYNET-I/O
Страница 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0A090...
Страница 6: ...Table of Contents ADVANCED MICRO CONTROLS INC 6 Notes...
Страница 26: ...Limit Switch Functionality ADVANCED MICRO CONTROLS INC 2 26 Notes...
Страница 36: ...Additional Functionality ADVANCED MICRO CONTROLS INC 3 36 Notes...
Страница 90: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...