20 Gear Drive, Plymouth Ind. Park, Terryville, CT 06786
Tel: (860) 585-1254 Fax: (860) 584-1973 http://www.amci.com
Introduction to the ANS1
1
15
Module Specifications
Number of I/O Words (16 bits each)
20 input words and 20 output words
Physical Dimensions
Width: 1.8 inches max.
Depth: 4.5 inches max.
Height: 3.9 inches
5.0 inches min. with mating connectors
Weight
0.50 lbs. (0.23 kg.) with mating connectors
Position Sensor
Resolver or Quadrature Encoder (4X decode)
Multiple units can be slaved together over a serial
link.
Number of Outputs
(16) 8 Relay Outputs, 8 DC Sourcing Outputs
Number of Inputs
16 DC inputs.
(8) DC Sourcing Inputs on relay board
(8) DC Sinking Inputs on module
Throughput Time
Master ....... 10 to 20 microseconds
Depending on load and programming
Slave ......... 50 microseconds
Web Interface Default IP
192.168.0.40 (Programmable from interface.)
Limit Switch Functionality
Maximum of sixteen outputs
Four on/off setpoint pairs per output
Separate on/off advances per output
Fixed and Variable advances available for
brake/clutch control
Timer functionality (Interval On)
... 1 to 32,767 milliseconds
Enable ANDing
Output can be tied to one or more inputs
Speed Enable (RPM between setpoints)
High Enable (Input must be active)
Pulse Enable (Input must pulse within
output’s setpoint pairs.)
Window Enable (Input must pulse within
programmable window’s setpoint pairs.)
Shift Register (Associated bit position in shift
register must equal ‘1’.)
Shift Register
256 bits. Updated once per machine cycle.
Logic ‘1’ placed in register’s first bit if input
active during programmed sensing window.
Die Protection Monitors
(16) Monitors.
Activated when an input is assigned to it.
Normally True Check
Normally False Check
Cyclic Check
Constant Check
Pulse Check
Each monitor has an 8 bit fault counter.
Output can be assigned to monitor to signal fault
condition.
Brake Monitor
Monitors starting & stopping times of the machine
Resolution ............ 1 millisecond
Range ................... 1 to 32,767 milliseconds
Reports:
Starting Position
Starting Time
Brake Applied Position
Stopping Time
Production Counters
Machine Revolutions
Program Cycles
(3) Batch Counters
Good Part Counter
Range ................................. 0 to 999,999,999
Counters can be preset to any value within their
range.
Batch Complete Outputs
Separate outputs can be assigned to the Machine
Cycle counter and each of the three batch coun-
ters to signal when the counter has reached its
programmable setpoint.
Part Cycle Counter
Good Part Counter
Machine Revolution Counter
Programmable Fault Outputs
Die Protection Fault
Start Time Fault
Stop Time Fault
Status LED’s
starting on page 11.
Содержание ANS1 ANYNET-I/O
Страница 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0A090...
Страница 6: ...Table of Contents ADVANCED MICRO CONTROLS INC 6 Notes...
Страница 26: ...Limit Switch Functionality ADVANCED MICRO CONTROLS INC 2 26 Notes...
Страница 36: ...Additional Functionality ADVANCED MICRO CONTROLS INC 3 36 Notes...
Страница 90: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...