Input Data Format
6
83
Data Attribute 16: Machine Status Data
(continued on next page)
EtherNet/IP
Address
Modbus
Address
Bit Number
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
Ackno
wled
ge
Heartbeat
Ha
rd
wa
re
Fa
ult
Resolver Fault
Program Fault
Bits
RPM Clamped
Output Forced
0
1
0
0
0
0
1
1
Machine Position
2
2
Machine Speed in RPM
When using a resolver, the sign of value indicates direction of
rotation. With default programming and wiring, the value is
negative for counter-clockwise rotation.
3
3
Production Rate
(Machine Speed * Production Multiplier / Production Divisor)
4
4
Time of Rotation
Time it took for the shaft to complete its last rotation. Resolution of
0.1 milliseconds. (A value of ‘123’ means the last rotation took 12.3
milliseconds to complete.)
5
5
State of Inputs
(Bit 0 = Input 1 ... Bit 15 = Input 16)
6
6
Selected Input Point Number
(See Word 3, Command Block 1, page 54.)
7
7
Rising Position of Selected Input
Last position where the input made an inactive-to-active transition.
8
8
Falling Position of Selected Input
Last position where the input made an active-to-inactive transition.
9
9
State of Outputs
(Bit 0 = Input 1 ... Bit 15 = Input 16)
10
10
Calculated State of Outputs
(Bit 0 = Input 1 ... Bit 15 = Input 16)
Output state with advances, but without Enabling or Timed
parameters applied.
11
11
Simple Enabled Outputs
(Bit 0 = Input 1 ... Bit 15 = Input 16)
These bits are normally ‘1’. A bit is reset to ‘0’ if the output is
disabled by an input configured for Simple ANDing.
12
12
Pulse Enabled Outputs
(Bit 0 = Input 1 ... Bit 15 = Input 16)
These bits are normally ‘1’. A bit is reset to ‘0’ if the output is
disabled by an input configured for Pulse ANDing.
13
13
Windowed Enabled Outputs
(Bit 0 = Input 1 ... Bit 15 = Input 16)
These bits are normally ‘1’. A bit is reset to ‘0’ if the output is
disabled by an input configured for Window ANDing.
14
14
Shift Register Enabled Outputs
(Bit 0 = Input 1 ... Bit 15 = Input 16)
These bits are normally ‘1’. A bit is reset to ‘0’ if the output is
disabled because the associated bit in the Shift Register equals ‘0’.
Содержание ANS1 ANYNET-I/O
Страница 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0A090...
Страница 6: ...Table of Contents ADVANCED MICRO CONTROLS INC 6 Notes...
Страница 26: ...Limit Switch Functionality ADVANCED MICRO CONTROLS INC 2 26 Notes...
Страница 36: ...Additional Functionality ADVANCED MICRO CONTROLS INC 3 36 Notes...
Страница 90: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...