20 Gear Drive, Plymouth Ind. Park, Terryville, CT 06786
Tel: (860) 585-1254 Fax: (860) 584-1973 http://www.amci.com
Output Data Format
5
63
Command Block 6: Program LS Enabling Parameters (continued)
Command Word Bits (continued)
Bit 8:
Program Input Enable Conditions.
When set to ‘0’ the use of the remaining data block words is
determined by bits 9 and 10. When set to ‘1’, the remaining output words define what, if any, Input
ANDing is used to control the output limit switch defined by data block word 1.
1) Position Window Low and High Limits are only used if one of the inputs is configured for
Window ANDing.
2) Each output can have multiple inputs assigned to it, but only one of these inputs can be
configured for Window ANDing. Multiple outputs can use the same input as their Window
ANDing input.
3) A full description of output enabling can be found in the
section of
this manual, starting on page 23.
Word
Result
1
LS Output Point being programmed (1 to 16)
2
Input 1 ANDing
0: Input 1 is not used for Enable ANDing with the LS output.
1: Simple ANDing
2: Pulse ANDing
3: Window ANDing
3
Input 2 ANDing.
Range of 0 to 3. (See definition in Word 2 above)
4
Input 3 ANDing.
Range of 0 to 3. (See definition in Word 2 above)
5
Input 4 ANDing.
Range of 0 to 3. (See definition in Word 2 above)
6
Input 5 ANDing.
Range of 0 to 3. (See definition in Word 2 above)
7
Input 6 ANDing.
Range of 0 to 3. (See definition in Word 2 above)
8
Input 7 ANDing.
Range of 0 to 3. (See definition in Word 2 above)
9
Input 8 ANDing.
Range of 0 to 3. (See definition in Word 2 above)
10
Input 9 ANDing.
Range of 0 to 3. (See definition in Word 2 above)
11
Input 10 ANDing.
Range of 0 to 3. (See definition in Word 2 above)
12
Input 11 ANDing.
Range of 0 to 3. (See definition in Word 2 above)
13
Input 12 ANDing.
Range of 0 to 3. (See definition in Word 2 above)
14
Input 13 ANDing.
Range of 0 to 3. (See definition in Word 2 above)
15
Input 14 ANDing.
Range of 0 to 3. (See definition in Word 2 above)
16
Input 15 ANDing.
Range of 0 to 3. (See definition in Word 2 above)
17
Input 16 ANDing.
Range of 0 to 3. (See definition in Word 2 above)
18
Position Window Low Limit (0 to (
Full Scale Count
-1))
19
Position Window High Limit (0 to (
Full Scale Count
-1))
Содержание ANS1 ANYNET-I/O
Страница 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0A090...
Страница 6: ...Table of Contents ADVANCED MICRO CONTROLS INC 6 Notes...
Страница 26: ...Limit Switch Functionality ADVANCED MICRO CONTROLS INC 2 26 Notes...
Страница 36: ...Additional Functionality ADVANCED MICRO CONTROLS INC 3 36 Notes...
Страница 90: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...