20 Gear Drive, Plymouth Ind. Park, Terryville, CT 06786
Tel: (860) 585-1254 Fax: (860) 584-1973 http://www.amci.com
Installing the ANS1
4
47
Relay Board Installation (continued)
RB-8 Outline Drawing
Figure 4.11 RB-8 Outline Drawing
Compatible Relays
Every output requires a solid state relay. The RB-7 and RB-8 are designed for OPTO 22 Generation 4 style
relays. There relays are fused protected, and have a retaining screw and indicator LED. AC and DC relays are
available from AMCI under the following part numbers.
Figure 4.12 Compatible Relays
AMCI Part #
Opto 22 Part #
WRC Part#
Output Voltage
Rated Current
KD-6
G4ODC24
WRC4-OBXS11
3 to 60 Vdc
3 Adc
KA-3
G4OAC24
WRC4-OAXS
120 Vac
3 Aac
U
U
U
U
U
U
U
U
K1
K2
K3
K4
K5
K6
K7
K8
U
FUSE
TESTER
DS1
F1
SPARE FUSE
FROM
MODULE
CN1
+
+
+
+
4/12
+
5/13
+
6/14
+
7/15
+
8/16
COM +24V
GND
E1
8.25 in
2.25" max.
(57.2)
2.85" max.
(72.4)
2.50" typ.
(63.5)
1.77" typ.
(45.0)
3.80"
(96.5)
0.65" (16.5) typ.
7.999 in
8.00" (203.2) Suggested Mounting Dimension
7.7" (196) typical dimension with brackets reversed)
1/9
2/10
3/11
COM
E2
Содержание ANS1 ANYNET-I/O
Страница 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0A090...
Страница 6: ...Table of Contents ADVANCED MICRO CONTROLS INC 6 Notes...
Страница 26: ...Limit Switch Functionality ADVANCED MICRO CONTROLS INC 2 26 Notes...
Страница 36: ...Additional Functionality ADVANCED MICRO CONTROLS INC 3 36 Notes...
Страница 90: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...