Data Attribute 4: Die Monitor Setup Data
Figure 6.6 Die Monitor Setup Format (Data Attribute 4)
Check Mode Values
EtherNet/IP
Address
Modbus
Address
Bit Number
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
0
Ackno
wled
ge
Heartbeat
Ha
rd
wa
re
Fa
ult
Resolver Fault
Program Fault
Bits
RPM Clamped
Output Forced
0
0
0
1
0
0
1
1
Fault Output Point Number
‘0’ if no fault output is associated with this Die Protection monitor.
2
2
Selected Input Point Number
(See Word 3, Command Block 1, page 54.)
3
3
Check Mode (See description below.)
4
4
Check Window 1 Leading Edge
5
5
Check Window 1 Trailing Edge
6
6
Check Window 2 Leading Edge
7
7
Check Window 2 Trailing Edge
8
8
Check Window 3 Leading Edge
9
9
Check Window 3 Trailing Edge
10
10
Check Window 4 Leading Edge
11
11
Check Window 4 Trailing Edge
12
12
Die Monitor Action Mode (See description below.)
13-19
13-19
Not Used
Check Mode
(Word 3 Value)
Result
0
Disable Die Protection Monitoring on the input given in word 2.
1
Normally True Check
(Setpoints in words 4-11 are not used.)
2
Normally False Check
(Setpoints in words 4-11 are not used.)
3
Cyclic Check
4
Constant Check
5
Quick Check
Содержание ANS1 ANYNET-I/O
Страница 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0A090...
Страница 6: ...Table of Contents ADVANCED MICRO CONTROLS INC 6 Notes...
Страница 26: ...Limit Switch Functionality ADVANCED MICRO CONTROLS INC 2 26 Notes...
Страница 36: ...Additional Functionality ADVANCED MICRO CONTROLS INC 3 36 Notes...
Страница 90: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...