Command Block 10: Program Production Cycle Parameters
This block allows you to program the Production Cycle parameters, which affect the part counters available
on the ANS1.
Figure 5.13 Command Block 10
Command Word Bits
Bit 8:
Program Production Cycle Increment Position Parameter.
If this bit is reset to ‘0’ the Production
Cycle Increment Position parameter is left at its previous value. If this bit is set to ‘1’, the Production
Cycle Increment Position parameter is set to the value contained in word 1.
Bit 9:
Program Production Cycle Multiplier / Divisor Parameters.
If this bit is reset to ‘0’ the Production
Cycle Multiplier and Production Cycle Divisor parameters are left at their previous values. If this bit
is set to ‘1’, the Production Cycle Multiplier parameter is set to the value contained in word 2 and the
Production Cycle Divisor parameter is set to the value contained in word 3.
EtherNet/IP
Address
Modbus
Address
Bit Number
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
1024
T
ransmit Bi
t
0
0
0
0
0
Ap
ply
W
o
rd
s
2&
3
Apply W
o
rd 1
0
0
0
Clear Error
1
0
1
0
1
1025
Production Cycle Increment Position
(Range of 0 to (
Full Scale Count
-1))
2
1026
Production Cycle Multiplier
(Range of 1 to 32,767)
3
1027
Production Cycle Divisor
(Range of 1 to 32,767)
4 - 19
1028-1043
Not Used
Содержание ANS1 ANYNET-I/O
Страница 1: ...MICRO CONTROLS INC ADVANCED U s e r M anual Manual 940 0A090...
Страница 6: ...Table of Contents ADVANCED MICRO CONTROLS INC 6 Notes...
Страница 26: ...Limit Switch Functionality ADVANCED MICRO CONTROLS INC 2 26 Notes...
Страница 36: ...Additional Functionality ADVANCED MICRO CONTROLS INC 3 36 Notes...
Страница 90: ...LEADERS IN ADVANCED CONTROL PRODUCTS ADVANCED MICRO CONTROLS INC...