System Reset
Program Reset
The AGP-2000 program can be reset to the default values if needed. A System Reset
is accomplished through the Test Mode.
1. Press the
POWER
button on the remote control unit.
2. Press
2
to enter the Test Mode.
3. Enter your four digit password and press the
VOL DOWN
button.
4. Press
7
to enter the System menu.
5. Press
2
to select RESET.
6. Press
1
for YES if you wish to RESET the program.
Note
: All program parameters will be reset to the AGP-2000 default values.
7. Press the
VOL DOWN
button to Reset the AGP-2000 Program and return to the
Main Test menu.
8. Press the
POWER
button to return to the Normal Mode.
Clearing the Ram
If it becomes necessary to completely clear the memory and return the system to
it’s default configuration, you must temporarily disconnect the battery located on the
back of the Main PCB as follows:
1. Turn off the machine
2. Disconnect the comms cables (see Figure 3-4).
3. Using needle nose pliers, carefully pull the negative battery lead from its socket.
Caution: Use extreme care to make sure neither the pliers or the battery lead
contacts any runs on the circuit board.
4. Wait at least 5 seconds and carefully re-insert the lead into its socket, connect
the comms cables and turn on the machine.
AGP-2000 Installations and Operations / SERVICE
4 - 9
Содержание AGP-2000 Series
Страница 1: ...AGP 2000 Series Ticket Dispenser INSTALLATION OPERATIONS MANUAL ...
Страница 2: ......
Страница 4: ......
Страница 6: ...ii AGP 2000 Installation and Operations TABLE OF CONTENTS ...
Страница 8: ...1 2 AGP 2000 Installation and Operations INTRODUCTION ...
Страница 14: ...2 6 AGP 2000 Installation and Operations SPECIFICATIONS ...
Страница 26: ...AGP 2010 Schematic 3 12 AGP 2000 Installation and Operations INSTALLATION Figure 3 13 AGP 2010 Schematic ...
Страница 38: ...4 10 AGP 2000 Installation and Operations SERVICE ...
Страница 39: ......