Page 1: ...User s manual for water softeners with 85SE control valve FUTURA LOTUS EN Technology works for you ...

Page 2: ...de 14 11 Troubleshooting 15 6 1 Button definition 4 6 2 Programming mode 4 6 2 1 Data input procedure 4 6 2 2 Time setting 5 6 2 3 Setting language and region 5 6 2 4 Setting feedwater hardness and number of people 6 6 2 5 Setting regeneration mode 6 6 2 6 Setting the time of regeneration 7 6 2 7 Setting regeneration frequency in days 7 6 2 8 Setting the amount of treated water 7 6 2 9 Setting cyc...

Page 3: ...ow Scale deposits on the heating elements increase the energy consumption for waterheating Hard water can also lead to water supply installation and household appliances damages which removal can be expensive Moreover hard water increases detergent consumption and creates stains onfixtures UST M s water softeners soften water so effectively thanks to the usage of high quality ion exchange resin Th...

Page 4: ...e parts Avoid moving across the floor It is forbidden to drop the device putting it on sharp or angular edges and turning upside down because this may lead to permanent damage of the softener The device shouldbe transportedonlyinanuprightposition otherwiseit maydamage thecontroller Wheninstallingthesoftener make sure youhave the knowledge orhire a professional make sure the placement area is clean...

Page 5: ...by pass flexible hoses pressure gauge 210 230V water softener Drain hose must be installed on drain elbow using a clamp Installation scheme 6 Programming Headis controlledbya simple software Large LCDdisplayshowsbasicinformations suchas n Time anddate n Waterflow n Regenerationmode n Date of thepreviousregeneration n Volumeofwaterremains untilthe nextregeneration ATTENTION THIS SOFTENER WORKS ONLY...

Page 6: ...buttonfor3 seconds n PresstheMENUbuttontoenter themainmenu n PresstheUP orDOWNbuttontoselectdesired parameter n PresstheSET REGENbutton currentvaluewill starttoflash n PresstheUP orDOWNbuttontochangethe values n PresstheSET REGENbuttontosave the settings n PresstheUP orDOWNbuttontoselectanotherparameter n Repeat thesesteps untilallparametersare set n PresstheMENUbuttontoexit the mainmenu ATTENTION...

Page 7: ...REGENbutton n SetcurrentdayofamonthusingtheUP DOWNbuttons n Confirm bypressingtheSET REGENbutton n Press the DOWNbutton n Press the SET REGENbutton n Setcurrentyear usingthe UP DOWNbuttons n Confirm bypressingtheSET REGENbutton n Press the MENUbutton Time n SetMETRICorUSGALLONusingthe UP DOWNbuttons n Confirm bypressingtheSET REGENbutton n Select LANGUAGEusingthe UP DOWNbuttons n Confirm bypressin...

Page 8: ...elected digit n Set numberof peopleusingtheUP DOWNbuttons n Confirm bypressingthe SET REGENbutton n PresstheMENUbuttontwice Settings Regeneration mode 6 2 5 Setting regeneration mode Futuracanoperate inthefollowingregenerationmodes Calendar clock controller will start regeneration after a specified number ofdays Meter immediate controller will start regeneration immediately treating specified amou...

Page 9: ...uency in days n Press the MENUbutton n Select REGENERATIONDAYSusingthe UP DOWNbuttons n Confirm bypressingtheSET REGENbutton n Press the SET REGENbutton to activate selecteddigit n Set number of days between regenerations using the UP DOWN buttons n Confirm bypressingtheSET REGENbutton n Setminutesusingthe UP DOWNbuttons n Confirm bypressingtheSET REGENbutton n Press the MENUbutton Regen Days Rege...

Page 10: ...ow inautomaticoperationmode Regen Cycle 15 6 2 10 Restoring defaults n PresstheMENUbutton n SelectRESTORE DEFAULTSusingtheUP DOWN buttons n Confirmby pressing the SET REGENbutton n PresstheMENUbutton3 times ATTENTION Skipthisstepifthedeviceworksproperly n Initiating this mode will delete all settings and return to the factorydefaults Restoring defaults 7 Start up procedure n Set theby passvalve in...

Page 11: ...etopen n Open a tap in a possibly highest point of the object and wait for venting n Wait until the end of BACKWASHING 1 Time remaining is shown on a display n Wait until the end of RINSING Time remaining is shown on a display n Wait until the end of REFILLING Time remaining is shown on a display n Wait until preparing to work message disappear Amount of water Delay Immediat Rinsing 1 Rinsing 2 Re...

Page 12: ... on the left side of the controller or by using a by passvalve Turning the screw clockwise the hardness of water supplied to the object is increased Water hardness can also be adjusted by turning the blend adjusting knob on a by pass valve in a way shown on the picture below You can also adjust water hardness supplied to the object the higher angle of turn A the higher water hardness ATTENTION If ...

Page 13: ...rom brine during a ion exchange resin regeneration process This function can be activated or deactivated according to ones needs When activated the generator will produce free chlorine during every regeneration n In order to unlock the device press and hold the MENU button for 3seconds n Press the MENUbuttonagain n Press the UP button Salt Check iconwillbe highlighted n Confirm bypressing theCONFI...

Page 14: ...ingtheCONFIRM button n Activate or deactivate the function by pressing the UP orDOWN buttons n Confirmby pressingtheCONFIRM button n Afterconfirmationyouwillautomaticallyexittomenu n Press the MENU button in order to return to the stand by mode Activation deactivationofthe free chlorinegenerator Residual chlorine generator Signal line Brine line Brine tank Residual chlorine generator ...

Page 15: ...nerating in the regeneration ON OPEN the salt alarm OFF CLOSE the residual chlorine generating in the regeneration OFF CLOSE the salt alarm MUNICIPAL HIGH EFFICIENCY TIME OF DAY YEAR MONTH DAY SET HARDNESS The instruction of residual chlorine generator and salt alarm When the salt level is normal the screen will show NORMAL When the salt level is lacking the screen will show CHECK and flash Betwee...

Page 16: ...l ofmicroorganismsatthesame time During holiday mode the device does not draw salt To set the softener in a HOLIDAY MODE do the following n PresstheMENUbutton n SelectHOLIDAYMODE usingthe UP DOWNbuttons n Confirmby pressing the SET REGENbutton n SelectACTIVATEusingtheUP DOWNbuttons n Confirmby pressing the SET REGENbutton n Set the end of the holiday mode Set every following digit using the UP DOW...

Page 17: ...nerate the resin Hard water Internal valve leak Replace gaskets spacers and or piston Salt bridge was formed Test with a broom handle Break the bridge and remove its pieces Regeneration mode was not set Set regeneration mode Carry out manual regeneration Float jammed Disassemble and clean parts Hard water salt level does not change Injector plugged Disassemble and clean injector Increased water co...

Page 18: ...er Contact your local dealer Lack of upper basket Excess water in brine tank Injector plugged Clean or replace injector Clean flow control Clean injector Clean flow control Clean the tank Foreign material in brine tank Plugged drain line flow control DLFC Softener fails to draw brine Control cycles continuously Plugged DLFC Plugged injector Low water pressure Internal control leak Increase water p...

Page 19: ...www ustm pl UST M Sp z o o ul Piaskowa 124A 97 200 Tomaszów Maz Poland e mail biuro ustm pl Technology works for you ...