manualshive.com logo in svg
background image

Installation and Operation:
1. Remove cabinet cover.   Drill holes for the three wall anchors with a 5/16" drill bit, using the cabinet back as a template
for

proper spacing of the mounting screws. Install mount-

ing anchors, and then screws in top two anchors. Slide key holes in

cabinet back over screw heads, tighten screws,

then install bottom screw. Do not mount more than 6 feet (1.8 meters) above

the bottom of the concentrate con-

tainer, nor below the highest concentrate level (never mount your concentrate higher than

the propor-

tioner).
2. Select a metering tip (see next section), and insert into hose barb on eductor body. (Repeat for all eductors.)
3. Supply tube should reach from hose barb on eductor to bottom of the concentrate container. Cut supply tube provided to

length required. Slide a ceramic weight over one end of tube and slide a foot valve into the same end of the tube. (Prepare
a tube for each eductor.)

4. Slip other end of supply tube through an opening in either side of the cabinet and push over the hose barb/metering tip
on

the eductor. (Repeat for all eductors.)

5. Place foot valve ends of supply tubes into concentrate containers. REMEMBER TO CHECK FOOT VALVE STRAINERS

PERIODICALLY FOR CLOGGING: CLEAN IF NECESSARY.

6. A short  discharge tube is used with the 1GPM eductor; minumum tube length is 8 inches (20cm) for proper operation.

Longer tubes (4 feet) are used with a 4 GPM eductor.  Do not remove the flooding rings from inside the tubes.  Slide end
of tube with flooding ring over eductor discharge outlet. (Repeat for all eductors.) Hooks may be installed on longer tubes
to allow discharge tube to conveniently hang from dispenser when not in use.

7. Replace cabinet cover. Push the sides in, behind the latch holes, to snap the cover in place. The two screws provided may

be installed in the holes in the cabinet sides to prevent easy removal of cover.

8. Connect water supply hose of at least 1/2" ID to water inlet swivel. (Minimum 25 PSI pressure, with water running, is required

for proper operation.) Connect opposite end of hose to water supply. Turn water supply on.

9. Push button to start flow of desired water/concentrate solution, and hold until supply tube is primed (filled). Then push the

button whenever dispensing is desired, and release button to stop flow of solution. If you wish to be able to lock the button
in the "on" position: 
clip or bend the two tabs behind the lower front portion of the

button (see diagram).  This allows the

button to be

fully depressed and allows it to latch in the "on" position.  To unlock, pull

t h e

button out.

AccuDose 

Series Proportioner

1, 2, or 3 button units

Package Should Contain:
1. Proportioner unit.
2. Supply tubing.
3. Foot valve assembly & weight for each eductor.
4. Discharge tube for each eductor.
5. Metering tip kit(s).
6. Mounting anchor kit.
7. Hook(s) for discharge tube(s) -- Models with 4 GPM eductors only.
8. Instruction sheet.

Clip or
bend
these tabs
to
depress
button
into
locked
position.

THANK YOU FOR YOUR INTEREST IN OUR PRODUCTS

Please use this equipment carefully and observe all warnings and cautions.
****************************************************** NOTE ****************************************************

protective clothing and eyewear when dispensing chemicals or other
materials.

observe safety and handling instructions of the chemical manufacturers.

direct discharge away from you or other persons or into approved containers.

dispense cleaners and chemicals in accordance with manufacturer's
instructions.   Exercise CAUTION when maintaining your equipment.

equipment clean to maintain proper operation.

protective clothing and eyewear when working in the vicinity of all
chemicals, filling or emptying equipment or changing metering tips.

re-assemble equipment according to instruction procedures. Be sure all
components are firmly screwed or latched into position.

only to tap water outlets (85 PSI maximum).

ALWAYS

ALWAYS

ALWAYS

WEAR

ALWAYS

WEAR

KEEP

ATTACH

Содержание AccuDose series

Страница 1: ...he cabinet sides to prevent easy removal of cover 8 Connect water supply hose of at least 1 2 ID to water inlet swivel Minimum 25 PSI pressure with water running is required for proper operation Connect opposite end of hose to water supply Turn water supply on 9 Push button to start flow of desired water concentrate solution and hold until supply tube is primed filled Then push the button whenever...

Страница 2: ...ser for a minute or so and note two things the amount of dispensed solution and the amount of concentrate used in preparation of the solution dispensed The water to product ratio is then calculated as follows Dilution Ratio X 1 where X Amount of Mixed Solution Amount of Concentrate Drawn Amount of Concentrate Drawn Dilution Ratio then equals X parts water to one part concentrate X 1 If the test do...

Страница 3: ...button unit shown 9 10075980 Valve parts kit a diaphragm b armature c spring d valve bonnet 10 10079010 Spring 11 10079000 Magnet 12a 10035310 Vacumn breaker b 270702 Washer 13a 441205 1 GPM eductor b 441200 4 GPM eductor c 3401 r Hose barb assembly 14a 6422 A 1 GPM discharge tube 7 b 90048495 4 GPM discharge tube 4 15 690014 Metering tip kit 16 500870 Tubing 1 4 x 7 17 509900 Weight 18 10076301 F...

Страница 4: ...tip or eductor has b Clean descale or replace scale build up c Low water pressure c Minimum 20 PSI with water running required to operate unit properly d Discharge tube not in place d Push tube firmly onto eductor discharge hose barb e Concentrate container empty e Replace with full container f Inlet hose barb not screwed f Tighten but do not overtighten into eductor tightly g Clogged water inlet ...

Отзывы: