Main Power Connections
12. Connect the GROUND wire from the field wiring to the GREEN wire inside the
Field Connect Box.
13. Replace the cover plate over the Field Connect Box.
14. Connect the power source to field wiring only after all terminal block
connections have been made. (See the following sections.) Then proceed
as follows:
15. Turn both Main Power Breakers ON.
16. Turn the Logic Power Switch ON. The switch will illuminate when it is in the
ON position.
Connection Locations
Refer to Figure 3-3 below for the location of the Communication Interconnect PCB
À
,
the Field Connections Terminal Block TB2
Á
and the I/O Rack
Â
. The illustration also
shows the optional secondary I/O Rack (AGP-0502/A527)
Ã
installed.
3 - 4
AGP-2000 Installation and Operations / INSTALLATION
Figure 3-3, Field Connection Locations