INSCRIPTION
7.
INSCRIPTION
Table 1
7 — LEDs 19 (
Figure 8, Figure 9
)
LED
INSCRIPTION PURPOSE
LIGHT ON
LIGHT OFF
LR
Radio control command (the LED lights up in red if the
remote control is not recorded or the control command is
not assigned to the control button / lights up in green if
the control command is assigned to the control button)
Is supplied
Is not supplied
LOP
Command to open (input
OP
, connector 20)
Is supplied
Is not supplied
LCL
Command to close (input
CL
, connector 20)
Is supplied
Is not supplied
LSBS
Command to open, stop, close (input
SBS
, connector 20)
Is supplied
Is not supplied
LP
Command to partially open (input
P
, connector 20)
Is supplied
Is not supplied
LS
Safety device in the STOP circuit:
• input
S
, connector 20
• connector 18 or contacts
IN_S
and
O_S
of connector 11
(section ‘5.2. Connection of switches / drive encoder’)
Is activated Is not activated
LA
Input command
A
(connector 20)
Is supplied
Is not supplied
LPH1
Photocell safety device (input
PH1
, connector 20)
Is activated Is not activated
LCL.L
End position CLOSED
(for drive with switches input
CL.L
, connector 16)
Closed
Not closed
LOP.L
End position OPEN
(for drive with switches input
OP.L
, connector 16)
Open
Not open
LP.L
*
Disabling the built-in obstacle detection system
P5
–
F1
(
Table
13). For drive with switches, the releasing of input
P.L
, connector 16)
Is turned off Is not turned off
L5.L
Disabling the safety edge
P5
–
F7
(
Table
13) and / or the slow
speed starting
P5
–
P9
.
For drive with switches, the releasing of input
P.L
,
connector 16)
Is turned off Is not turned off
Table 1
8 — Control panel inscription 14 (
Figure
8,
Figure
9)
INSCRIPTION
DESCRIPTION
Standby mode (display shows one dot)
Opening
Closing
The end position OPEN (for drive with switches, input
OP.L
is activated connector 20)
The end position CLOSED (for drive with switches, input
CL.L
is activated connector 20)
Partially open position (by the input command
P
of the connector 20 or by the
command PARTIALLY OPEN of the radio remote control)
Opening command is activated
* Only for control unit CU-TR230.
Содержание CU-TR230
Страница 2: ......
Страница 44: ......
Страница 86: ......
Страница 126: ...Control units СU TR230 СU TR400 124 124 200 310 164 270 R40 90 118 244 271 350 377 2 3 ...
Страница 129: ...Control units СU TR230 СU TR400 127 127 8 14 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 ...
Страница 130: ...Control units СU TR230 СU TR400 128 128 9 14 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 ...
Страница 136: ...Control units СU TR230 СU TR400 134 134 5 L GND P L GND CL L O_S 16 OP L IN_S P1 F0 01 MENU S5 NO CU TR TR COM NC NO 24 ...
Страница 137: ......