CONTROL UNITS СU-TR230 / СU-TR400
108
108
SETTINGS
MENU
SETTING
DESCRIPTION
VALUES
FACTORY
VALUE
P8
F4
Lighting operation time after the command
of the radio control LIGHTING ON.
The operat-
ing time of the lighting lamp is set in the case
of recording a remote control for lighting con-
trol (LIGHTING command,
Table
4)
no
— lighting lamp
does not turn off
according to time
(it turns off only at
the command of the
remote control)
01, 02
…
99:
01
— 1 min
99
— 99 min
no.
F7
Operating time LOAD № 1 after the command
of the remote control LOAD № 1 ENABLE.
The
operating time of the outputs of the connectors
7
–
9
(value
13
,
Table
14) is configured in the case
of recording the remote for load control (LOAD
command № 1,
Table
4)
no
— load does not
turn off according
to time (it turns
off only at the
command of the
remote control)
01
,
02
…
99:
01
— 1 min
99
— 99 min
no.
F8
Operating time LOAD № 2 after the command
of the remote control LOAD № 2 ENABLE.
The
operating time of the outputs of the connectors
7
–
9
(value
14
,
Table
14) is configured in the case
of recording the remote for load control (LOAD
command № 2,
Table
4)
no
— load does not
turn off according
to time (it turns
off only at the
command of the
remote control)
01
,
02
…
99:
01
— 1 min
99
— 99 min
no.
P0
F0
Reset to factory settings.
See section ‘6.4. Reset to factory settings’
F1
Cycle counter.
See section ‘6.5. Cycle counter data’
Table
14 describes the operating modes of the outputs of connectors
7
–
9
(
Figure
8 /
Figure
9).
When setting the value (
P3
–
F4
…
F6
), the outputs of the connectors (relay contacts of the control
unit) will operate in accordance with the specified logic. The figure shows the normal status of
the outputs (relay contacts of the control unit).
JX.3
JX.2
JX.1
7-9
NO
NC
COM
NO
— normally open contact
NC
— normally closed contact
Содержание CU-TR230
Страница 2: ......
Страница 44: ......
Страница 86: ......
Страница 126: ...Control units СU TR230 СU TR400 124 124 200 310 164 270 R40 90 118 244 271 350 377 2 3 ...
Страница 129: ...Control units СU TR230 СU TR400 127 127 8 14 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 ...
Страница 130: ...Control units СU TR230 СU TR400 128 128 9 14 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 ...
Страница 136: ...Control units СU TR230 СU TR400 134 134 5 L GND P L GND CL L O_S 16 OP L IN_S P1 F0 01 MENU S5 NO CU TR TR COM NC NO 24 ...
Страница 137: ......