CONTROL UNITS СU-TR230 / СU-TR400
91
91
ELECTRICAL CONNECTIONS
OPTION 2.
Installation with four external fasteners (
Figure
3). On the base of the control unit
body, use screws 4 (
Figure
1) to install at the required mounting angle 3 (
Figure
1). Then mark
the fixing points on the mounting surface and fix the unit.
5.
ELECTRICAL CONNECTIONS
Y
ATTENTION!
For electrical connections make sure that the mains power is disconnected (cir-
cuit breaker of the mains power is off)!
Follow electrical safety regulations!
Y
Use a puller to remove the connectors. Gently pull with the puller by the connector (
Figure
6),
if necessary, in several locations along the length of the connector.
The door control buttons and the display window are located on the unit body cover (
Figure
7).
The buttons are connected to the electronic module of the unit by the manufacturer.
5.1
NETWORK AND ELECTRIC DRIVE CONNECTIONS
The network connection is performed to connector 1 of the unit (CU-TR230 —
Figure
8,
CU-TR400 —
Figure
9).
L
is phase (phases),
N
is neutral. Protective earth is connected to connector
2
.
Y
When connecting to the network, there should be provided a device disconnecting all poles
from the network (for instance, automatic circuit breaker), which ensures full disconnection
under conditions of over-voltage category III. The device should be installed in accordance
with Electrical Installations Code and located at easily accessible place, at convenient and safe
height (1.5–1.9 m).
The electric drive is connected to connector
10
.
The connection of connectors
4
and
12
is performed by the manufacturer
• Network and electric drive TP series (230 V ~) connection to the CU-TR230 control unit is
presented in
Figure
10.
• Network and electric drive TP series (400 V 3~) connection to the CU-TR400 control unit is
presented in
Figure
11.
Y
When connecting the electric drive to the control unit, first read the section on electrical con-
nections of the drive manual. Identify the required cable and the wire marking of cable sup-
plied with the drive.
5.2
CONNECTION OF SWITCHES / DRIVE ENCODER
• Connection a driver TR series with mechanical switches is shown in
Figure
12.
Limit switches (
B
) of drive are connected to
OP.L
and
CL.L
contacts. Function switches (
A
)
of drive are connected to
5.L
and
P.L
contacts, which must be used when switching on in
the unit menu the settings
P5
–
F7
and
P5
–
F1
(
Table
13), respectively. Сontact
P.L
is not used
in the CU-TR400 control unit!
Y
Make sure that connector
18
is installed with a crossbar (is included in complete kit).
If there is no connector with a crossbar, connect a crossbar between the
IN_S
and
O_S
contacts of connector
16
. When connecting the electric drive to the control unit, first
read the section on electrical connections of the drive manual. Identify the required
cable and the wire marking of cable supplied with the drive
Содержание CU-TR230
Страница 2: ......
Страница 44: ......
Страница 86: ......
Страница 126: ...Control units СU TR230 СU TR400 124 124 200 310 164 270 R40 90 118 244 271 350 377 2 3 ...
Страница 129: ...Control units СU TR230 СU TR400 127 127 8 14 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 ...
Страница 130: ...Control units СU TR230 СU TR400 128 128 9 14 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 ...
Страница 136: ...Control units СU TR230 СU TR400 134 134 5 L GND P L GND CL L O_S 16 OP L IN_S P1 F0 01 MENU S5 NO CU TR TR COM NC NO 24 ...
Страница 137: ......