CONTROL UNITS СU-TR230 / СU-TR400
92
92
ELECTRICAL CONNECTIONS
• Connection a drive TR series with encoder is shown in
Figure
13. Connection is performed
using the cable provided with the drive.
Y
ATTENTION!
When using a drive with encoder, make sure that there are no connec-
tions (crossbars, switches) to connector
16
of the unit.
5.3
CONNECTION OF ADDITIONAL DEVICES
Y
When operating, installing and connecting additional electrical devices (accessories), the man-
uals supplied with these devices must be observed. Incorrect connection may result in malfunc-
tion of the product. Use additional devices (accessories) offered by ALUTECH Conpany and with
the required characteristics. ALUTECH Company is not responsible for the operation of the drive
system when using additional devices produced by other manufacturers.
Designation of connectors and connector contacts in
Table
2:
CU-TR230 —
Figure
8, CU-TR400 —
Figure
9
Table 2
CONNECTOR
CONTACT
DESCRIPTION
20
A
The input of the ‘OPEN / CLOSE’ control devices (
Figure
14,
ALARM
) with
a normally open contact (
NO
). Depending on the direction selected in the
settings (
Table
13,
P7
–
F5
), actuation the input will open or close the doors.
During the operation (closure) of the input, all other control commands are not
executed
OP
The input of the control devices ‘Open’ (
Figure
14,
OPEN
) with a normally open
contact (
NO
). The control command OPEN is executed when actuation with
the factory settings. The logic of operation depends on the settings (
Table
13,
P3
–
F8
)
GND
General contact
CL
The input of the control devices ‘Close’ (
Figure
14,
CLOSE
) with a normally open
contact (
NO
). The control command CLOSE is executed when actuation
SBS
The input of the control devices ‘Step by step’ (
Figure
14,
STEP BY STEP
) with a
normally open contact (
NO
). The control command STEP BY STEP is executed
when actuation with the factory settings. The logic of operation depends on
the settings (
Table
13,
P3
–
F8
)
P
The input of the control devices ‘Pedestrian’ (
Figure
14,
PEDESTRIAN
) with
a normally open contact (
NO
). With the doors fully closed (in the final closing
position), the actuation will open the doors during the time set in the setting
(
Table
13,
P1
–
F9
)
S
The input of the control devices ‘Stop’ (
Figure
14,
STOP
) with a normally closed
contact (
NC
). Actuation will immediately stop the door movement or block the
start of the door movement
+24 V
Power output of additional devices. Supply voltage 24 V DC (DC) / max. 250 mA
+12 V
Power output of additional devices. Supply voltage 12 V DC (DC) / max. 150 mA
Содержание CU-TR230
Страница 2: ......
Страница 44: ......
Страница 86: ......
Страница 126: ...Control units СU TR230 СU TR400 124 124 200 310 164 270 R40 90 118 244 271 350 377 2 3 ...
Страница 129: ...Control units СU TR230 СU TR400 127 127 8 14 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 ...
Страница 130: ...Control units СU TR230 СU TR400 128 128 9 14 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 ...
Страница 136: ...Control units СU TR230 СU TR400 134 134 5 L GND P L GND CL L O_S 16 OP L IN_S P1 F0 01 MENU S5 NO CU TR TR COM NC NO 24 ...
Страница 137: ......