CONTROL UNITS СU-TR230 / СU-TR400
93
93
ELECTRICAL CONNECTIONS
CONNECTOR
CONTACT
DESCRIPTION
20
SE
Security resistive edge connection input 8.2 kOhm (
Figure
14,
8K2
) or optical
safety edge connection (
Figure
15,
OSE
). In the settings (
Table
13,
P7
–
F4
), the
type of edge (sensor) is set. Contact of the door leaf with an obstacle when
closing (actuation of the installed sensor) will stop the door movement and
then open it (
Table
13,
P5
–
F5
)
PH1
Security device input (photocells,
Figure
16) with normally closed contact
(
NC
). Actuation when closing will stop the door movement and then open it
(
Table
13,
P5
–
F5
), or block the start of closing
PHT
An output for automatic verification the operation of photocells (PHOTOTEST)
connected to the input
PH1
. In the settings (
Table
13,
P7
–
F3
), the PHOTOTEST
is enabled. Before starting the movement, briefly turning off, then turning on
the power of photocells, an automatic verification of the photocell operation is
performed.
An example of a scheme for connecting photocells with a power off of the
photocell transmitter is shown in
Figure
16. An example of a scheme for
connecting photocells with a transmitter powered by batteries is shown in
Figure
17
7–9
J1.1– J1.3
Normally open (
NO
) relay
contact
Potential-free relay outputs (dry contact).
Maximum load: no more than 3 A.
The relay operating mode is set in the settings
(
Table
13,
P3
–
F4
…
F6
). The relay operating
modes are described in
Table
14
J2.1– J2.3
General relay contact
J3.1– J3.3
Normally closed (
NC
) relay
contact
11
L (L1)
Outputs 230 V / 50 Hz for powering additional devices. Maximum load no more
than 3 A
N
15
GND
Input connection of shielding antenna conductor
ANT
GND
15
RG58
ANT
Input connection of signal antenna conductor
17
LOCK
Switch connector with key (option). The switch is installed on the unit body.
Using the key, the switch is transferred to the (NC) position, which blocks the
commands of the control devices (unit buttons, control switches, radio remote
controls, etc.), or to the (NO) position, in which control is enabled.
LO
C
K
17
NC
Control is blocked
LO
C
K
17
NO
Control is enabled
Содержание CU-TR230
Страница 2: ......
Страница 44: ......
Страница 86: ......
Страница 126: ...Control units СU TR230 СU TR400 124 124 200 310 164 270 R40 90 118 244 271 350 377 2 3 ...
Страница 129: ...Control units СU TR230 СU TR400 127 127 8 14 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 ...
Страница 130: ...Control units СU TR230 СU TR400 128 128 9 14 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 ...
Страница 136: ...Control units СU TR230 СU TR400 134 134 5 L GND P L GND CL L O_S 16 OP L IN_S P1 F0 01 MENU S5 NO CU TR TR COM NC NO 24 ...
Страница 137: ......