CONTROL UNITS СU-TR230 / СU-TR400
112
112
SETTINGS
6.6
INPUT А OPERATION (SETTING P7–F5–AL)
If the value
АL
is selected in setting
P7
–
F5
, the control command of the connection input
А
(
Table
2) will lead to doors movement to the previously set intermediate position of opening
(for example, 2.5 m) or to the complete doors opening. When stopping at the previously set re-
quired intermediate position, the unit will display inscription
АL
.
Y
ATTENTION!
Only during holding (closing) input
А
all other control commands are ignored and
will not be executed (block control inputs, radio remote controls, buttons, etc.). The connected
safety devices during opening (input
S
,
Table
2) remain active (safety commands are executed).
Pressing the button
of the control unit (3,
fig.
7) will stop the movement of doors; after re-
leasing the button, the actuation (closure) of input ‘
А
’ will be executed. When the
P7
–
F5
–
AL
set-
ting is enabled, the
P5
–
F1
setting (obstacle detection at opening) is disabled (does not operate).
SETTING THE INTERMEDIATE POSITION OF THE DOORS OPENING
WHEN SELECTING P7–F5–AL
1. Drive with switches (P1–F0–01)
:
It is necessary to connect to the control unit (
fig.
24) and set the free cam / switch of the
TR
se-
ries drive (for example, cam
E
, or consequently switch
S5
) to operate in the required intermedi-
ate position. Refer to the drive manual for the description of cams and switches location in the
drive, as well as adjusting the cam position.
Y
ATTENTION!
Beforehand, it is necessary to change the wire on the switch from the
NC
contact
to the
NO
contact (
fig
. 24)!
Y
ATTENTION!
If the cam / switch of the drive is not connected and set, then by the command of
input control
A
doors will be fully opened.
Y
ATTENTION!
If doors at the moment of input
A
actuation was higher than the set intermediate
position, then doors will be fully opened.
2. Drive with encoder (P1–F0–02):
After turning on the
P7
–
F5
–
АL
setting, the
P1
–
F7
setting (
Table
13) will be used to set the in-
termediate doors opening for input control
A
.
After entering the
P1
–
F7
setting using
or
button, set the doors to the required
position and press the button
to confirm the set position. The display shows the inscrip-
tion
AL
with a dot (
AL.
).
Y
ATTENTION!
If the
P1
–
F7
setting is not activated (not set), then by the command of input con-
trol
A
the doors will be fully opened.
Содержание CU-TR230
Страница 2: ......
Страница 44: ......
Страница 86: ......
Страница 126: ...Control units СU TR230 СU TR400 124 124 200 310 164 270 R40 90 118 244 271 350 377 2 3 ...
Страница 129: ...Control units СU TR230 СU TR400 127 127 8 14 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 ...
Страница 130: ...Control units СU TR230 СU TR400 128 128 9 14 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 ...
Страница 136: ...Control units СU TR230 СU TR400 134 134 5 L GND P L GND CL L O_S 16 OP L IN_S P1 F0 01 MENU S5 NO CU TR TR COM NC NO 24 ...
Страница 137: ......