SAFETY RULES AND WARNINGS
devices against the door leaf fall. The doors should have safety devices (switches) against ten-
sion slackening and breakage of the door leaf lifting cable.
The product cannot be used if the door wicket is open. It is allowed to use it only with the wick-
et being closed. Doors design should ensure deactivation of the product operation (the doors
should be equipped with a wicket sensor / it is not included in the product package) if the door
wicket is open.
The dangerous part of the doors and the drive should be at least 2,5 m above the floor or oth-
er access level. Otherwise, a person should be protected from injuries in dangerous areas. The
door leaf should not have holes more than 50 mm in diameter, or unprotected edges and pro-
truding parts, which a person could grab or stand on when opening the doors. Parts of the doors
and the drive should not extend beyond the footpath and common access areas or block them.
Remove or deactivate mechanical blocking devices of doors movement (locks or latches, lock-
ing devices) that are not involved in the product operation.
Remove all unnecessary parts before installation and turn off all unnecessary equipment.
Make sure that there is enough space for installation and operation of the product.
Make sure that the drive system devices are protected against accidental impact by passing ve-
hicle. Otherwise, provide protective equipment (fences).
The surfaces of the installation locations of the devices must be durable and must be used as a
reliable and rigid support, eliminating vibration. Otherwise, take measures to strengthen the in-
stallation locations. The control unit and other stationary control devices must be located with-
in the visibility of doors at a height of not less than 1.5 m and at a safe distance from moving el-
ements. Control devices should not be publicly available.
In the case of using radio remote controls, make sure that the installation location of the con-
trol unit provides high-quality radio signal reception (there are no shielding and reflective sur-
faces, other sources of radio emission). Otherwise, take measures to ensure the operation of the
radio control (for example, the use of an external antenna).
The electrical network must be equipped with protective earth connection. Make sure that the
earth connection system is correctly designed and connected.
The section of the electrical network to which the product is connected must be equipped with
a suitable short circuit protection device (circuit breaker or other equivalent device) in accord-
ance with the features of the network and the product.
The electrical cables of the control and safety devices must be laid separately from the mains
voltage cables. Cables should be protected from contact with any rough and sharp surfaces;
use corrugations, pipes and cable entries when laying cables. For electrical connection of drive
system components, use double insulated copper multi-strand cable. The features of used elec-
tric cables (cross-section, number of wires, length, etc.) must correspond to the connection di-
agram, device power, laying distance, laying method, and external conditions.
It is necessary to provide protection against crushing, impact, trapping, tightening and other haz-
ards (EN 12604, EN 12453), it could be achieved by the installation of safety devices; installation of
protective designs; maintaining safe distances and clearances, setting up the product. The opera-
tion of safety devices such as a safety edge or photo line (light curtain) must comply with the re-
quirements of standards (EN 12978, EN 13849). Ensure safe operation of doors with automatic drive.
When operating outside the doors visibility zone or when automatic closing of doors is activat-
ed in the settings, photocells (or an equivalent safety device) must be installed.
The product and the entire drive system can be finally put into operation only when its con-
firmed that the door and the structure its built-in correspond to the requirements and direc-
tives of the existing local rules and regulations.
Содержание CU-TR230
Страница 2: ......
Страница 44: ......
Страница 86: ......
Страница 126: ...Control units СU TR230 СU TR400 124 124 200 310 164 270 R40 90 118 244 271 350 377 2 3 ...
Страница 129: ...Control units СU TR230 СU TR400 127 127 8 14 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 ...
Страница 130: ...Control units СU TR230 СU TR400 128 128 9 14 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 ...
Страница 136: ...Control units СU TR230 СU TR400 134 134 5 L GND P L GND CL L O_S 16 OP L IN_S P1 F0 01 MENU S5 NO CU TR TR COM NC NO 24 ...
Страница 137: ......