CONTROL UNITS СU-TR230 / СU-TR400
117
117
MALFUNCTIONS AND RECOMMENDATIONS FOR THEIR ELIMINATION
10. MALFUNCTIONS AND RECOMMENDATIONS
FOR THEIR ELIMINATION
Y
ATTENTION!
When looking for the cause of an incorrect operation or malfunction, refer to the
description of the control unit inscription: LEDs (
Table
17) and display (
Table
18).
Y
ATTENTION!
In the event of malfunction that cannot be resolved using the information in this
manual, you must contact the service department.
Table 1
9
MALFUNCTION
PROBABLE CAUSE
RECOMMENDATIONS
No inscription of control unit
No mains voltage
Check mains voltage
No network connection
Check cable connections with mains
voltage (section 5.1)
Fuse has blown
Check control unit mains fuses (
Table
20)
Drive does not operate
(there is an inscription of the
control unit
E0
or
E5
)
Drive type with
switches is incorrectly
selected in the settings
(with encoder or
switches)
Check the drive type in setting
P1
–
F0
(
Table
13)
Error in electrical con-
nections
Check the connections of the switch /
encoder of the drive (section 5.2)
Stop motion devices
are activated (e.g. wick-
et sensor)
Make sure that the inputs of the normally
closed contact devices are closed (input
S
,
Table
2, connector 20)
Drive is unlocked
Check that the drive is locked (drive
manual)
Drive in emergency
manual control mode
Check the position of the unit handles
with the drive chain (drive manual)
End positions of the
drive with encoder are
not set
Set the end positions of drive (section 6.1,
item 2 and item 3)
Drive with encoder does
not operate (there is an
inscription of the control
unit
EE
)
Incorrect direction of
the drive opening with
encoder
Check the opening direction of
P1
–
F1
(section 6.1, item 2)
Check the correct installation of the drive
relative to the doors (section 6.1, item 3)
There is no signal from
the encoder
Check the encoder connection
Doors are not controlled by
the radio remote control
(the indicator on the remote
control ‘does not light or
does not light brightly’,
the distance of the remote
control operation is small)
Remote control bat-
tery is low
Check the battery of the remote control;
replace it if necessary (see the manual of
the radio remote control)
Содержание CU-TR230
Страница 2: ......
Страница 44: ......
Страница 86: ......
Страница 126: ...Control units СU TR230 СU TR400 124 124 200 310 164 270 R40 90 118 244 271 350 377 2 3 ...
Страница 129: ...Control units СU TR230 СU TR400 127 127 8 14 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 ...
Страница 130: ...Control units СU TR230 СU TR400 128 128 9 14 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 ...
Страница 136: ...Control units СU TR230 СU TR400 134 134 5 L GND P L GND CL L O_S 16 OP L IN_S P1 F0 01 MENU S5 NO CU TR TR COM NC NO 24 ...
Страница 137: ......