CONTROL UNITS СU-TR230 / СU-TR400
114
114
INSCRIPTION
INSCRIPTION
DESCRIPTION
Closing command is activated
Stop of movement according to the STOP control command
Control command is activated from input
A
(connector 20)
Control command is activated from input
P
(connector 20) or PARTIALLY OPEN
command of the radio remote control is activated
Input
A
is activated (connector 20)
Operation of control devices is blocked. The pins of connector 17 (LOCK) are closed
(
Table
2)
Counting pause time until automatic closing
End position error.
For a drive with switches
the following may be:
• end position switches are open / input
OP.L
and input
CL.L
are activated
(connector 16)
• in the setting
P1
–
F0
, the value 01 is not set (
Table
13)
For a drive with encoder
the following may be: end positions are not set (section
‘6.1. Setting end positions of doors’, item 3)
*
Built-in security obstacle detection
Safety device / photocells are activated (input
PH1
, connector 20)
Safety edge is activated (input
SE
, connector 20)
PHOTOTEST verification error (
Table
13,
P7
–
F3
)
Safety device in the STOP circuit is activated:
• input
S
, connector 20
• connector 18 or contacts
IN_S
and
O_S
of connector 11
(section ‘5.2. Connection of switches / drive encoder’)
Stop of movement at the end of operating hours (settings
P5
–
F3
,
P5
–
F4
)
No movement error (for a drive with encoder).
Make sure that the drive is locked. Check the connection of the drive motor. In the event
of malfunction that cannot be resolved, contact the service department
Settings read error. Make a reset to factory settings (Chapter 6.4)
Encoder data read error (for a drive with encoder), wrong encoder signal, malfunctions.
Check the connection of the encoder. In the event of malfunction that cannot be
resolved, contact the service department
There is no signal from the drive encoder: incorrect or broken encoder connection,
malfunction.
In setting
P1
–
F0
, the value 02 (
Table
13) for the drive with encoder is not set.
Mains voltage is low or there is a unit malfunction (T1A fuse,
Table
20)
* Only for control unit (settings
P5
–
F1
,
P5
–
F2
).
Содержание CU-TR230
Страница 2: ......
Страница 44: ......
Страница 86: ......
Страница 126: ...Control units СU TR230 СU TR400 124 124 200 310 164 270 R40 90 118 244 271 350 377 2 3 ...
Страница 129: ...Control units СU TR230 СU TR400 127 127 8 14 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 ...
Страница 130: ...Control units СU TR230 СU TR400 128 128 9 14 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 ...
Страница 136: ...Control units СU TR230 СU TR400 134 134 5 L GND P L GND CL L O_S 16 OP L IN_S P1 F0 01 MENU S5 NO CU TR TR COM NC NO 24 ...
Страница 137: ......