Setting General Trunk Attributes
178
AltiWare OE System Installation & Administration Manual
Trunk Seizure
Confirmation
Select from:
• Enable Dial Tone Detection (Outgoing)—
detection of outgoing dial tone.
• Enable Polarity Detection (Incoming)—
detection of incoming polarity. Polarity
detection is used when the CO or the connected
PBX provides polarity reversal on the tip and
ring.
Disconnect
Supervision
Select from:
• Tone—busy tone (reorder tone, fast busy tone,
error tone, etc.) or dial tone (continuous tone,
etc.). This should be used in conjunction with
drop in loop current. For COs who cannot
guarantee loop break, this may be the only
option.
• Polarity Reversal—a reversed battery signal.
You can set the Loop Break Signal to either
200 or 600 ms.
Receive Gain
Slide setting adjusts the incoming volume from
-6 dB to 6 dB for every Triton Analog Trunk channel.
The default setting is 0 dB, and it is highly recommended
not to change this setting.
Caution:
Setting the volume too high will cause
distortion in voice quality and/or missed
DTMF digits.
Transmit Gain
Slide setting adjusts the outgoing volume from
-6 dB to 6 dB for every Triton Analog Trunk channel.
The default setting is 0 dB, and it is highly recommended
not to change this setting.
Caution:
Setting the volume too high will cause
distortion in voice quality and/or missed
DTMF digits.
Parameter
Description
Содержание Altiware OE 4.5
Страница 2: ...AltiWare OE Version 4 5 System Installation and Administration Manual Revised 07 2002 4403 0001 4 5 ...
Страница 57: ...Key AltiServ Characteristics 28 AltiWare OE System Installation Administration Manual ...
Страница 117: ...Software Installation Troubleshooting 88 AltiWare OE System Administration Manual ...
Страница 129: ...Stopping the AltiGen Switching Service 100 AltiWare OE System Installation Administration Manual ...
Страница 169: ...Setting Logout Reason Codes 140 AltiWare OE System Installation Administration Manual ...
Страница 261: ...Setting Up Monitor Lists 232 AltiWare OE System Installation Administration Manual ...
Страница 283: ...Phrase Management 254 AltiWare OE System Installation Administration Manual ...
Страница 337: ...Changing TAPI Configuration Parameters 308 AltiWare OE System Installation Administration Manual ...
Страница 365: ...AltiWeb Security 336 AltiWare OE System Installation Administration Manual ...
Страница 375: ...Multisite Configurator 346 AltiWare OE System Installation Administration Manual ...
Страница 403: ...Advanced CallRouter 374 AltiWare OE System Installation Administration Manual ...
Страница 439: ...410 AltiWare OE System Installation Administration Manual ...