Loop Protection
With the loop protection feature enabled, configure the switch to shut down a port if detecting a loop in
the edge of the network. An undetected loop can cause a broadcast storm.
4.17.1
Configuration
To configure loop protection general and port settings via the web interface:
1. Navigate to
Configuration
>
Loop Protection
>
Configuration.
2. Specify the global loop protection settings, and then specify loop protection settings for each port.
3. Click
Apply
or Click
Reset
to revert to previously saved values.
0.
Figure 103:
Loop Protection
Parameter
Description
Enable Loop Protection
Enable/disable loop protection globally on the switch
Transmission Time
The interval between each loop protection PDU sent on each port. Valid values are
1 – 10 seconds.
Shutdown Time
The period for which a port will be kept in disabled state in the event a loop is
detected. Valid values are 0 – 604800 seconds. A value of 0 will keep the port
disabled until next device reboot.
Port
Indicates the port number
Enable
To enable loop protection on the port
Action
The action performed when a loop is detected. Options are Shutdown Port,
Shutdown Port and Log or Log Only
Tx Mode
Controls whether the port is actively generating loop protection PDUs or is just
passively looking for PDUs.
Toll Free 1-866-
ALLWORX • 585
-421-
3850 •
www.allworx.com
Revised: October 30, 2013
Page 149
Содержание PowerFlex P810
Страница 1: ...PowerFlex 8 24 48 Port GbE PoE Managed Switch User s Guide Updated October 30 2013...
Страница 2: ......
Страница 3: ...PowerFlex 8 24 48 Port GbE PoE Managed Switch User s Guide...
Страница 235: ......
Страница 236: ...Toll Free 1 866 ALLWORX 585 421 3850 www allworx com Version 1 Revised October 7 2013...