CAUTION
If the end cap becomes loose at
any time, do not retighten. Remove
end cap and clean thoroughly. Pay
special attention to cleaning the
threads of end cap and body. Lubri-
cate threads as instructed in the
maintenance section, then re-
assemble according to Section 9.8.
6.2.8 Reversing The Hole-Hog
If the Hole-Hog meets an obstacle or devi-
ates from course, stop the tool and reverse
it out of the hole. The tool may also be
stopped and returned when a blind hole is
required.
To reverse the tool, proceed as follows:
1.
Stop compressed air delivery by closing
the air supply valve.
2.
Disconnect the hose at the connector
nearest the hole entry.
3.
Untwist the hose attached to the tool
along its entire length and position it in
line with the hole.
NOTE
To reverse the tool, the valve must be
located at the extreme rear position.
To reposition the valve assembly, the
hose must be turned counterclock-
wise.
4.
Twist the hose 3 or 4 turns counter-
clockwise and pull the hose taut. The
valve assembly should loosen and be-
gin turn counterclockwise.
5.
Continue to twist the hose until the
valve assembly is seated in its rear po-
sition.
6.
Reconnect the air hose and open the air
supply valve.
7.
If the tool fails to start, close and open
the air supply valve rapidly to induce a
sudden flow of air to start the tool.
8.
Increase air pressure to 100 psi
(7.0kg/cm
2
) and drive the tool out of
the hole. Never exceed 100 psi
(7.0kg/cm
2
). Pressures above 100 psi
(7.0kg/cm
2
) decrease tool life.
9.
When the tool has exited the hole, stop
the air supply and disconnect the hose.
10. To avoid damage to the valve assembly,
turn the hose or valve assembly clock-
wise to return the valve assembly to its
fully seated, forward most position.
6.2.9 Install Material in the Pierced Hole
Many attachments are available for the
Hole-Hog. Some of these install materials
in the pierced hole; for example: pipe driv-
ers and cable /tube pullers.
If one of these attachments is used to in-
stall material in the pierced hole:
1.
Refer to the manual provided with the
attachment and proceed as instructed.
2.
Once the material is installed in the
pierced hole, remove and service the
Hole-Hog as described in 6.2.10.
6.2.10 Remove and Service Hole-Hog
1.
When the Hole-Hog is no longer re-
quired for piercing or material installa-
tion, proceed as follows:
a. Stop compressed air delivery by clos-
ing the air supply valve.
A
LLIED
4000 Series Hole-Hog
17
Содержание 4001
Страница 1: ...HOLE HOG Models 4000 and 4001 Construction Products LLC TECHNICAL MANUAL Manual Part No 002052 ...
Страница 15: ...7 ALLIED 4000 Series Hole Hog 3 2 1 Figure 3 2 Hole Hog Decal Location Hole Hog CE Serial Number Plate ...
Страница 51: ...44 ALLIED 4000 Series Hole Hog This page intentionally left blank ...
Страница 67: ...60 ALLIED 4000 Series Hole Hog This page intentionally left blank ...
Страница 68: ...ALLIED 4000 Series Hole Hog 61 SECTION 14 0 PARTS WARRANTY INFORMATION ...
Страница 73: ......