AT-S41 User’s Guide
201
Phase 2
This phase to creating a new VLAN converts the tagged ports that you
added to the new VLAN into untagged ports. This process involves
changing the PVIDs of the ports so that they match the VID of the new
VLAN. For example, if you assigned the new VLAN a VID of 4, you must
change the PVIDs of the untagged ports to 4. The following procedure
explains how this is accomplished.
1. Click on the Advanced Config menu tab and select VLAN Config from
the sub-menu. Select VLAN Port Config
from the next sub-menu.
The VLAN Port Configuration page will appear, as displayed in
Figure 68.
Figure 68
VLAN Port Configuration
This page lists the ports on the switch and each port’s current PVID
assignment. For example, referring to the figure above, Ports 1 to 6 all
have a PVID of 1, meaning that they are untagged members of the
Default VLAN, which has a VID of 1.
By default, this window initially displays the PVIDs for the ports on the
master switch.
2. Use the Stack ID pull-down menu to select a switch in the stack that
contains ports that you want to identify as untagged ports of the new
VLAN. (You can skip this step to change to the master switch, since the
master switch is selected by default.)
3. Enter a new PVID value in the PVID field for the port number whose
PVID you want to change.