Chapter 5: Wiring the DC Connectors
68
Figure 29. Loosening the Captive Screws on the DC Connector
4. Remove 6.5mm (0.25 in.) of insulation from one end of the red voltage
wire and black RETURN wire. Refer to Figure 30.
Figure 30. Stripping a Stranded Power Wire
5. Insert the black and red wires into the power connector according to
Table 4. Secure them by tightening the captive screw with a flat-head
screwdriver. Allied Telesis recommends tightening the screw to 5 in-
lbs. Refer to Figure 31.
Table 4. Wire Connection Guide
–
+
Negative
Voltage
-48/-60 VDC
(red)
RETURN
(black)
Positive
Voltage
RETURN
(black)
48/60 VDC
(red)
6.5 mm
(0.25 in.)