Chapter 13: Virtual LANs
168
Enabled
- This parameter enables management access on this
VLAN.
Note
- If you enable management on a VLAN other than 1, you can
access management only through a tagged port of that VLAN.
- You can access management through the tagged port of all VLANs
on which you have enabled management.
- You can still access management through a port that is only an
untagged member of VLAN 1 and not a tagged member of another
VLAN.
Disabled
- This parameter disables
Management VLAN
on this
VLAN. If you change this parameter from
Enable
to
Disable
, the
Management VLAN
is still enabled on the
DefaultVLAN
.
Note
The Management VLAN is always Enabled on the untagged ports of
the DefaultVLAN. It cannot be disabled on the DefaultVLAN.
7. To assign ports to the VLAN, click on the port numbers labeled either
Static Tagged
or
Static Untagged
.
To assign all ports to the VLAN as
Static Tagged
, click
All
under
Static Tagged
.
To assign all ports to the VLAN as
Static Untagged
, click
All
under
Static Untagged
.
By default, all the ports are assigned to the
Not Member
category
when a specific VLAN is created. The
Not Member
ports are either
part of the DefaultVLAN (VLAN ID=1) or another VLAN.
8. Click
Apply
.
9. From the main menu on the left side of the page, select
Save Settings
to Flash
to permanently save your changes.
Modify a Tagged
VLAN
To modify the name or port assignments of a tagged VLAN, perform the
following procedure:
1. From the main menu on the left side of the page, select
Bridge
.
The
Bridge
folder expands.
2. From the
Bridge
folder, select
VLAN
.
The
VLAN
folder expands.
3. From the
VLAN
folder, select
Tagged VLAN
.
An example of a tagged VLAN is shown in the table at the bottom of
Figure 58.
Содержание AT-GS950/48
Страница 10: ...Contents 10...
Страница 14: ...Figures 14...
Страница 16: ...List of Tables 16...
Страница 20: ...Preface 20...
Страница 22: ...22...
Страница 62: ...Chapter 2 System Configuration 62...
Страница 64: ...64...
Страница 108: ...Chapter 6 Static Port Trunking 108...
Страница 124: ...Chapter 8 Port Mirroring 124...
Страница 186: ...Chapter 13 Virtual LANs 186...
Страница 194: ...Chapter 14 GVRP 194...
Страница 210: ...210...
Страница 224: ...Chapter 16 SNMPv1 and v2c 224...
Страница 242: ...Chapter 17 SNMPv3 242...
Страница 258: ...Chapter 18 Access Control Configuration 258...
Страница 272: ...Chapter 19 RMON 272...
Страница 302: ...Chapter 21 Security 302...
Страница 324: ...Chapter 23 LLDP 324...
Страница 338: ...338...
Страница 356: ...Chapter 27 LED ECO Mode 356...
Страница 360: ...Chapter 28 Energy Efficient Ethernet 360...
Страница 370: ...Chapter 29 Rebooting the AT GS950 48 370...
Страница 392: ...Appendix A MSTP Overview 392...