Chapter 13: Virtual LANs
160
VLAN Index
You must assign a unique number to each VLAN in a network. This
number is called the Port-Based VLAN Index. This number uniquely
identifies a VLAN in the AT-GS950/48 switch and across the network.
Each port of a port-based VLAN can belong to as many VLANs as
needed. Therefore, traffic can be forwarded to the members of the groups
to which the port is assigned. For example, port 1 and port 2 are members
of group 1, and ports 1 and 3 are members of group 2. In this case, traffic
from port 1 is forwarded to ports 2 and 3, traffic from port 2 is forwarded
only to port 1, and traffic from port 3 is forwarded only to port 1.
General Rules for Creating a Port-based VLAN
Here is a summary of general rules to observe when creating a port-based
VLAN:
Assign a unique name to each port-based VLAN.
Assign a unique VLAN Index to each port-based
VLAN. If a particular port-based VLAN spans multiple
switches, each part of the VLAN on the different
switches must be assigned the same VLAN index.
Create up to 52 port-based VLANs.
Tagged VLAN
Overview
The second type of VLAN supported by the AT-S116 Management
software is the
tagged VLAN
. In this type of VLAN, membership is
determined by tag information within the frames that are received on a port
and the VLAN configuration of each port.
The VLAN information within an Ethernet frame is referred to as a
tag
and
is contained in a
tagged header
for the frame. A tag, which follows the
source and destination addresses in a frame, contains the VLAN ID of the
VLAN to which the frame belongs (IEEE 802.3ac standard). This number
uniquely identifies each VLAN in a network.
When a switch receives a frame with a VLAN tag, referred to as a
tagged
frame
, the switch forwards the frame only to those ports whose VLAN ID
equals the VLAN tag.
A port that receives or transmits tagged frames is referred to as a
tagged
port
. Any network device connected to a tagged port must be IEEE
802.1Q compliant. This is the standard that outlines the requirements and
standards for VLAN tagging. The device must be able to process the
tagged information on received frames and add tagged information to
transmitted frames.
Содержание AT-GS950/48
Страница 10: ...Contents 10...
Страница 14: ...Figures 14...
Страница 16: ...List of Tables 16...
Страница 20: ...Preface 20...
Страница 22: ...22...
Страница 62: ...Chapter 2 System Configuration 62...
Страница 64: ...64...
Страница 108: ...Chapter 6 Static Port Trunking 108...
Страница 124: ...Chapter 8 Port Mirroring 124...
Страница 186: ...Chapter 13 Virtual LANs 186...
Страница 194: ...Chapter 14 GVRP 194...
Страница 210: ...210...
Страница 224: ...Chapter 16 SNMPv1 and v2c 224...
Страница 242: ...Chapter 17 SNMPv3 242...
Страница 258: ...Chapter 18 Access Control Configuration 258...
Страница 272: ...Chapter 19 RMON 272...
Страница 302: ...Chapter 21 Security 302...
Страница 324: ...Chapter 23 LLDP 324...
Страница 338: ...338...
Страница 356: ...Chapter 27 LED ECO Mode 356...
Страница 360: ...Chapter 28 Energy Efficient Ethernet 360...
Страница 370: ...Chapter 29 Rebooting the AT GS950 48 370...
Страница 392: ...Appendix A MSTP Overview 392...