© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
202065R6
98
Power Fail Recovery
The Power Fail Recovery feature allows the cycle status
to be saved in memory in the event of a power failure.
If a cycle is in progress when the power fails, the cycle
status is saved in memory. When power recovers, the
control will determine whether to automatically
continue the cycle from the point it left off, requiring
the user to press the START pad to continue the cycle,
or end the cycle and put the control into the Ready
Mode. To program this feature, refer to
Programming
Control
.
Power Fail Reset Disabled
If the Power Fail feature is disabled, the control will
automatically resume the cycle from the point it left
off.
Power Fail Reset Enabled
If the length of the power failure is less than the
programmed Power Failure Reset time, the control
will resume the cycle from the point it left off. The
cycle will resume automatically.
If the power failure lasted more than the programmed
power failure reset time, the control will end the cycle
and will return to the Ready Mode. If, however, the tub
is filled with water when the power recovers, the
control will not go directly to Ready Mode, but will
spin out the water first. In this case the control will
enter the Start Mode at the Rinse Spin #1 step of the
DELICATE Cycle prompting the user to press the
START pad. Once the START pad is pressed, the
control will start the Rinse Spin #1 step, then the Final
Spin step and then end the cycle.