© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
87
202065R6
Testing Machine and
Electronic Control Functions
This feature allows the owner to run diagnostic tests
on various washer operations without servicing the
washer. The following tests are available:
•
Control Software Version Number
•
Service Door Opening Test
•
Coin Vault Opening Test
•
Coin Drop #1 Input Test
•
Coin Drop #2 Input Test
•
Lid Switch Input Test
•
Pressure Switch Input Tests
•
Show Fill Time Test
•
Show Drain Time Test
•
Start Pulse Test
•
Configuration Display Test
•
Coin Drop Header Present Test
For an overview of the Manual Diagnostics Test
Feature, refer to the flowchart on the following page.
How to Enter Testing Feature
1. Control must be in Ready Mode. If it is not, rapid
advance through a cycle, refer to
Rapid Advance
Feature
, or if coins or a card has been entered,
refer to
Clear Vend Feature
.
2. Enter Manual Mode. Refer to
Entering the
Manual Mode
.
3. Press the DELICATES ( ) or the COLD ( )
keypad until “
diAg
” appears.
4. Press the START (enter) keypad. Display will
change to “
d001
” indicating the control software
version number test.
5. Press the DELICATES ( ) or the COLD ( )
keypad to scroll through the diagnostic test
options.
How to Start Tests
To start a diagnostic test, refer to the quick reference
chart below (
Table 11
). Press the START (enter)
keypad when the desired test number is displayed. For
detailed information on each test, read the appropriate
description.
How to Exit Testing Feature
Press the WARM (<) keypad until the display returns
to the previous mode of operation.
>
<
>
<
Diagnostic (Testing) Mode – Quick Reference Chart
Test Number
Diagnostic Mode
Display
“
d001
”
Control Software Version # Test
“
S XX
”
“
d002
”
Service Door Opening Test
“
S XX
”
“
d003
”
Coin Vault Opening Test
“
U XX
”
“
d004
”
Coin Drop #1 Input Test
“
C1XX
”
“
d005
”
Coin Drop #2 Input Test
“
C2XX
”
“
d006
”
Lid Switch Input Test
“
L XX
”
“
d007
”
AC Pressure Switch Test
“
P XX
”
“
d008
”
DC Pressure Switch Test
“
P XX
”
“
d009
”
Show Fill Time Test
“
FXXX
”
“
d010
”
Show Drain Time Test
“
dXXX
”
“
d011
”
Start Pulse Test
“
StXX
”
“
d012
”
Configuration Display Test
“
AXXX
”
“
d013
”
Coin Drop Header Present Test
“
CHXX
”
Table 11