© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
13
202065R6
Opening the Service Door
Coin Models
Manually programming the control requires the user to
open and close the service door. After opening and
closing the service door, access to various
programming options, diagnostics and audit
capabilities is allowed for 4.25 minutes.
The service door is located on the top of the meter case.
Refer to
Figure 3
.
Card Reader Models
Manually programming the control requires the user to
remove the control panel and unplug the bullet
connector located between the “white/black” and “red/
blue” wires. This will allow the user to access various
programming options, diagnostics and audit
capabilities. The control panel is located on the control
hood. Refer to
Figure 3
.
Any disassembly requiring the use of tools
must be performed by a suitably qualified
service person.
W299
WARNING
W521I
FLW6R
1
Service Door
2
Control Panel
Figure 3
FLW6R
W521I
1
2
CARD MODELS
COIN MODELS