© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Testing Machine and Electronic Control Functions
89
202065R6
Diagnostic Test Descriptions
Control Software Version Number Test
This option displays the control software version
number. To start test, control must be in the Testing
Mode. Refer to
“How to Enter Testing Feature”
at the
beginning of this section.
To enter, press the START (enter) keypad. The display
will show “
S XX
” where “
XX
” is the software version
number.
To exit the Software Version Number Test, press the
WARM (<) keypad. The control will return to the
testing mode.
Service Door Opening Test
This option tests the service door switch. To start test,
control must be in the Testing Mode. Refer to
“How to
Enter Testing Feature”
at
the beginning of this
section.
To enter, press the START (enter) keypad. The display
will show “
S oP
” when the service door switch is
open and “
S CL
” when the service door switch is
closed.
The service door switch has to be closed for at least
one second and opened for at least a half a second to
make a valid count. This test will add counts to the
service door opening counter for the audit and save the
date/time for each opening of the test.
To exit the Service Door Opening Test, press the
WARM (<) keypad. The control will return to the
testing mode.
Coin Vault Opening Test
This option tests the coin vault switch. To start test, the
control must be in the Testing Mode. Refer to
“How to
Enter Testing Feature”
at the beginning of this
section.
To enter, press the START (enter) keypad. The display
will show
“
U oP
” when the coin vault switch is open
and “
U CL
” when the coin vault switch is closed.
The coin vault switch has to be closed for at least one
second and opened for at least a half a second to make
a valid count. This test will add counts to the coin
vault opening counter for the audit and save the time/
date for each opening of the test.
To exit the Coin Vault Opening Test, press the
WARM (<) keypad. The control will return to the
testing mode.
Coin Drop #1 Input Test
This option tests coin drop #1. To start test, control
must be in the Testing Mode. Refer to
“How to Enter
Testing Feature”
at the beginning of this section.
To enter, press the START (enter) keypad. The display
will show “
C1XX
”. The “
XX
” will show the number
of coins entered. This test will add counts to the total
number of test coins #1 counter.
To exit the Coin Drop #1 Input Test, press the
WARM (<) keypad. The control will return to the
testing mode.
Coin Drop #2 Input Test
This option tests coin drop #2. To start test, control
must be in the Testing Mode. Refer to
“How to Enter
Testing Feature”
at the beginning of this section.
To enter, press the START (enter) keypad. The display
will show “
C2XX
”. The “
XX
” will show the number
of coins entered. This test will add counts to the total
number of test coins #2 counter.
To exit the Coin Drop #2 Input Test, press the
WARM (<) keypad. The control will return to the
testing mode.
Lid Switch Input Test
This test will display whether the washer lid is open or
closed.
To start test, control must be in the Testing Mode.
Refer to
“How to Enter Testing Feature”
at the
beginning of this section.
To enter, press the START (enter) keypad. If the lid is
closed, the display will show “
L CL
”
.
If the lid is
open, the display will show “
L oP
”.
To exit the test, press the WARM (<) keypad. The
control will return to the testing mode.