Programming Control
202065R6
82
32. Power Fail Reset “PFr”
This option allows the owner to set the amount of time
the control will store active cycle information in the
event of a power failure. The default setting for Power
Fail Reset is OFF. If Power Fail Reset is turned OFF,
the cycle will be saved.
How to Program Power Fail Reset
1. Control must be in Manual Mode. Refer to
Entering the Manual Mode
.
2. Press the DELICATES ( ) or the COLD ( )
keypad until “
Prog
” appears in the display. Press
the START (enter) keypad and “
AtS1
” will
appear in the display.
3. Press the DELICATES ( ) or the COLD ( )
keypad to scroll through the programmable
options until “
PFr
” appears in the display.
4. When “
PFr
” appears in the display, press the
START (enter) keypad “
oFF
” or a number will
appear in the display. This number corresponds to
the current Power Fail Reset setting.
5. Press the DELICATES ( ) or the COLD ( )
keypad to increase or decrease the current
number to the desired number selected from
Table 9
.
6. Press the START (enter) keypad when the correct
number appears in the display. The next option,
“
IrA
”, will appear in the display.
NOTE: To program
“IrA”
(IR Access [On/Off]),
refer to
option 33
. To program other options, refer
to the appropriate section.
How to Exit Programming Feature
Press the WARM (<) keypad until the control returns
to Ready Mode.
How to Read
Table 9
Use this table to set the amount of time for Power Fail
Reset.
“
oFF
” turns the option OFF. The current cycle status
will be saved. When power is restored, the cycle will
begin where it was interrupted.
If 133 is entered, the current cycle will be saved for up
to five minutes. If power is not restored within five
minutes, the control will erase the cycle status. The
minimum power failure time is five minutes. The
maximum power fail reset time is 127 minutes.
>
<
>
<
>
<
“PFr”
DISPLAY
TO ENTER IN STEP 6
POWER FAIL
RESET TIME
“
oFF
”*
Turned OFF. Cycle will be
saved.
133
5 minutes without power
before cycle is lost
. . . add one minute for every number up to
255
127 minutes without power
before cycle is lost
*Factory default setting.
Table 9