WARNING
CHECK THAT THE HOSE CONNECTIONS ARE TIGHT
(CHECK THE CLAMPS)! ANY LEAKAGE OF CHEMI-
CALS MAY CAUSE SERIOUS BODY INJURIES AS
WELL AS SERIOUS DAMAGE TO THE WASHER. IF
ONE OF THE NIPPLES ARE OPEN, CLOSE AND SE-
CURE THE OPENING WITH AN APPROPRIATE COV-
ER.
C088
ELECTRICAL CONNECTION
The power supply of the liquid soap pump system has to be con-
nected to an external electrical source. Only authorized workers
with a valid qualification must execute the electrical connection
on the machine according to the valid local standards. The correct
connection way can be found on the wiring diagram that is locat-
ed inside the cabinet in a plastic bag. Do not connect the liquid
soap pump system in the washer.
ELECTRONIC CONTROLLER WITH BLUE PCB AND
GRAPHICAL DISPLAY
For electric connection of supply control signals a plastic box is
available on the upper stand of the machine (see
the terminal box with LED signalization of activation of the re-
spective pump, (
). Under the terminal box there is a
label for electric connection,
. Detail connection of sig-
nals could be also found on the electric scheme of the machine.
Signals for supply pumps control are 24V AC. Maximum current
for control circuits of pumps must be limited to 10mA. Lead the
cable for connection of pumps control signals through the plastic
cable bushing,
. After connection of conductors to the
respective positions of the connector “P” (screw clamps), fix up
the cable by tightening the cable bushing) against disconnection
and close the box with the cover. For details about liquid soap
supply system programming, see Programming manual.
Electrical connection label
Figure 25
PUTTING THE MACHINE INTO OPERA-
TION
Before you put the machine into service, remove the four striking
transport braces securing the vibrating machine components dur-
ing the transport. The four striking braces are placed on the bot-
tom of the machine,
. They are available after de-
mounting of service panels,
them put service panels back on the machine.
WARNING
THE TRANSPORT BRACES MUST BE REMOVED
PRIOR TO PUTTING THE MACHINE INTO SERVICE.
FAILURE TO DO SO CAN RESULT TO MACHINE
DAMAGE.
C204
VERIFICATIONS: BEFORE PUTTING INTO SERVICE
1. A check of the transport braces removal,
.
2. Remove cabinet protective foil.
3. A check if the waste sump (or recycling) is ready for water
drainage.
4. A check of the protective connection (earthing/ground) - “PE”
or “PEN”.
5. A check of the vibration switch function during extracting and
the emergency function.
INSTALLATION
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
51
Part No. D1612ENR3