If the belts are too loose they can be slipping on the pulley and
cause a noisy operation. In the case of need, tighten the belts.
Change the belts if worn out or damaged.
is indicated testing force of belt tensioning which can
be measured by tension meter. Procedure for approximate belt
tensioning with belt deflection 20 mm: Apply a load of 5.5 kg to
the middle of the belt.
Force F measured by device
200 N
Table 10
BELT REPLACEMENT
NEVER USE A CROWBAR TO TAKE OFF THE BELTS
OVER THE PULLEY GROOVES.
Dismantling of the main drive belts is performed after loosening
the bolts of tightening roller on the right side of the drum and
loosening of the tightening bolt.
In case it is necessary to replace a belt of one drive including sev-
eral belts do not replace only one belt but replace all belts in one
time. Belts intended to be replaced shall be of identical type and
construction in the same set. After belts replacement check align-
ment of belt pulleys, tightening of belts and tightening of bolts
and nuts. Keep the belts and pulleys clean and protect them from
direct contact with oil, grease, water etc.
PULLEY ALIGNMENT
A precondition for the reliable operation and long lifespan of the
belts is proper pulley alignment. Inspect the alignment using a
ruler, placing it on the pulley faces. If all points (A, B, C, D) are
touching the ruler, the pulleys are aligned. If not, the pulleys must
be aligned. Realignment of belt positions shall be done if the rul-
er does not touch all points.
PULLEY ALIGNMENT
1.
Main housing with the pulley
2.
Drum
3.
Drive motor
4.
Ruler
Figure 30
WATER AND STEAM FILTERS
Machines are equipped with filters on water and steam inlets (if
the machine has steam heating). It is necessary to clean up the fil-
ters occasionally to avoid a prolongation of filling the machine
with water. Intervals of cleaning depend on the quantity of extra-
neous particles in the water line.
CLEANING THE FILTER
WARNING
BEFORE YOU START THE FILTER CLEANING PROC-
ESS, MAKE SURE THE HOT WATER (STEAM) INLET
IS CLOSED AND COLD.
C217
1. Stop the water (steam) inlet to the machine.
2. Unscrew the filter plug, (
,
filter sieve (
).
3. Clean the sieve with running water or with compressed air.
4. Put the sieve (
) and
MAINTENANCE
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
57
Part No. D1612ENR3