MACHINE [kg / lb / L]
26 / 57 / 265
33 / 73 / 332
44 / 97 / 442
66 / 146 / 663
Electrical heating 24 kW
kW
28
-
-
-
Electrical heating 36 kW
kW
-
40.5
-
-
Electrical heating 45kW
kW
-
-
53
-
Electrical heating 54 kW
kW
-
-
-
62
Steam or without heating
kW
4.5
8
Rated input power of the machine kW
28.5
40.5
-
-
Rated heating input power (elec-
trical heating only)
kW
24
36
45
54
SUPPLY PROTECTION DEVICE
Use “slow” type Protection devices (circuit breakers:
curve D
)
Residual current device (RCD)
mA
100, class B
Steam or without electrical heating
200 - 240V 3AC
A
32
50
380 - 480V 3AC
A
16
20
El. heating 18 kW (380-440V
3AC)
A
-
-
-
-
El. heating 18 kW (200-240V
3AC)
A
-
-
-
-
El. heating 18 kW (440V 3AC)
A
-
-
-
-
El. heating 24 kW (380-440V
3AC)
A
60 - 63
-
-
-
El. heating 24 kW (200-240V
3AC)
A
80
-
-
-
El. heating 36 kW (380-415V
3AC)
A
-
70
-
-
El. heating 36 kW (440V 3AC)
A
-
63
-
-
El. heating 36 kW (200-240V
3AC)
A
-
120
-
-
El. heating 45 kW (380-440V
3AC)
A
-
-
100
-
El. heating 45 kW (208-240V
3AC)
A
-
-
150
-
El. heating 54 kW (380-440V
3AC)
A
-
-
-
100
WASHING FUNCTIONS
Washing
RPM
45
41
Distribution
RPM
75
70
Table 2
continues...
TECHNICAL SPECIFICATION
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
26
Part No. D1612ENR3