N°
Failure mes-
sage
Failure
Action
Fault occurrence
E86
No RTC Comm
Real Time Clock is not available
For Info only.
End cycle
(Barrier Washers only)
E100
Weigh No
Comm
Communication fault weighing sys-
tem
Full Stop Tumble
Before Start
(Barrier Washers)
Whole Cycle
(Barrier Washers) (Barrier
Washers & FS23-55 only)
E101
Weigh Low
Weight machine is too low
Don't Start
Before Start
(Barrier Washers & FS23-55
only)
E102
Weigh High
Weight machine is too high
Don't Start
Before Start
(Barrier Washers & FS23-55
only)
E103
Weigh Balance
Weight is not balanced over 4 load
cell's.
Don't Start
Before Start
(Barrier Washers & FS23-55
only)
E104
Weigh Overload
Weight on individual load cell ex-
ceeds max.
Full Stop Tumble
Whole Cycle
(Barrier Washers & FS23-55
only)
E105
Weigh Airbags
No functional air pressure system
Don't Start
Before Start
(Barrier Washers 70 kg/154
lb/700 L, 90 kg/198 lb/900
L, 110 kg/243 lb/1100 L,
140 kg/309 lb/1400 L and
180 kg/397 lb/1800 L only)
E300-
E353
MITS ERR
Specific Mitsubishi Inverter Alarm
Full stop + safety time
Whole cycle
E400-
E441
KEB ERR
Specific KEB Inverter Alarm
Full stop + safety time
Whole cycle
E500-
E515
MEMORY ERR Memory Error
Full stop + safety time
Any time
E550
DAQ VERSION
ERR
Wrong DAQ Memory version
For Info only
While installing new software
E551
DAQ WRITE
ERR
Problem writing DAQ Memory
For Info only
Traceability function, whole
cycle
E552
DAQ FULL
ERR
DAQ Traceability Memory is Full
For Info only
Traceability function, whole
cycle
Table continues...