Get Diagnostic Status from Modules by Using Explicit Messaging
Appendix A
The tables show the I/O data supported by each module. See
and Reference Data on page 140
for data arrangements.
For I/O data, safety connections for up to four items, including one output,
can be allocated for the master unit. Also, standard connections for up to two
items can be allocated for the master unit.
1732ES-IB16
Safety
205 and 23
1732ES-IB8XOB8
Safety
204 and 22
1732ES-IB8XOBV4
Safety
204 and 22
Table 42 - 1791ES-IB8XOBV4 Modules
Input Data
Input Status
Assembly Instance
Safety
None
204
(1)
(1) The default Assembly Instance.
Point Status - Muting
334
Combined Status - Muting
324
Safety - Readback
Point Status - Muting
354
Point Status - Muting - Test Output
374
Output Data
Assembly Instance
Safety
–
234
Test
22
Combined
2C4
None
C7
Table 43 - 1791ES-IB16 Modules
Input Data
Input Status
Assembly Instance
Safety
None
205
Point Status - Muting
335
Point Status - Muting - Test Output
365
Combined Status - Muting
315
Point Status
225
(1)
(1) The default Assembly Instance.
Output Data
Assembly Instance
Test
–
23
None
C7
Table 41 - Default I/O Data
Module Cat. No.
Safety Connection
Assembly Instance (hex)
Содержание 1732ES-IB12XOB4
Страница 6: ...6 Rockwell Automation Publication 1791ES UM001G EN P November 2016 Table of Contents Notes ...
Страница 8: ...8 Rockwell Automation Publication 1791ES UM001G EN P November 2016 Summary of Changes Notes ...
Страница 38: ...38 Rockwell Automation Publication 1791ES UM001G EN P November 2016 Chapter 2 About the Modules Notes ...
Страница 174: ...174 Rockwell Automation Publication 1791ES UM001G EN P November 2016 Index Notes ...
Страница 175: ......