alemite Carbon Shield Service Guide | 45
www.alemitecarbonshield.com
specifications
Electrical systems
voltage
120 vAC or 240 vAC
Current
20 A @ 120 vAC,
10 A @ 240 vAC
Controller
Modular PLC platform
Annunciator
Touch screen color panel
(HMI)
Control
Close loop PID control;
temperature, pressure,
and flow. Adaptive
control mode
Analog Inputs
(3), 4-20 mA
Digital Outputs
(7)
Analog Outputs
(1)
Digital Inputs
(1)
Thermocouple
(2) inputs max
Alarms
High/low ranges for
oil, air temperature,
mist pressure, and
oil level.
Leakage, blockage,
change in oil adjustment
screw setting, and
abnormality of any
transducer operation.
Graphic Display
Temperature, pressure,
and mist density trending
Security
Two level password
access
Mist Density
Quantifiable oil to
air ratio
Comm. Options
Ethernet and Modbus
Display Languages
English
Measurement Units English and Metric
Содержание Carbon Shield